GBCS 16.2 / 0x81B5 / Message Patterns

Flow Sensor Detects Air in Gas Flow

WAN: YGeneric Alert Structure
Generating Device

Message Pattern

Success Examples

—
Alert triggeredDevice (internal)

The device detects the condition and generates GBCS event/alert code 0x81B5.

2
DeviceAlertMessageDevice → DSP (WAN)

The device transmits a GBCSResponse/DeviceAlertMessage to the DSP via the WAN. Payload contains alert code and timestamp only (Generic Alert Structure).

—
Alert received and validatedDSP (internal)

DSP authenticates the GBCSResponse against the device certificate and validates the alert content.

4
Alert delivered to Known Remote PartyDSP → Known Remote Party

DSP delivers the alert to the relevant Known Remote Party based on the alert code and triggering device type. The DUIS Response (sr:Response) wraps the raw GBCS payload in sr:GBCSPayload (base64).

—
Alert converted to MMC via ParseKnown Remote Party (internal)

The DCC User runs the received DUIS Response through the Parse tool, which decodes the GBCS payload and produces an ra:GBCSResponse (MMC) document containing the structured alert data.

MMC parse output structure (DUIS Annex 18 section 18.4.3)ra:GBCSResponse
MMC Output (ra:GBCSResponse) — SupplierMMC