DCC Alert

N22 — Failure to deliver Update Firmware Command to CSP / S1SP

SMETS applicability: All

Trigger & context

When and why this alert fires

Event
Failure to deliver Update Firmware command to CSP / S1SP
Trigger
Failure to receive an acknowledgement notification from a CSP / S1SP via the SM WAN for an Update Firmware Command
Recipient(s)
Update Firmware request sender
SMETS applicability
All
Payload DUIS applicability
>= 1.0

DUIS delivery

Wrapper and field names

Wrapper element
DCCAlertMessage
Alert code field
DCCAlertCode
Payload field
DCCAlert
Throttling supported
Yes

Payload structure (16.2.1)

FirmwareDistributionFailuresr:FirmwareDistributionFailure

This payload element is shared across multiple DCC alert codes:N18N19N20N21N22N23

Firmware Distribution Command to the CSP has failed for at least some Devices.

FieldTypeMandatoryDescriptionSensitivity
UpdateFirmwareRequestIDsr:RequestIDTypeYesRequest ID of the Update Firmware Service Request associated to the Command that failed.Non-Sensitive
MeterIDssr:DeviceIDListYesComma-separated list of Device IDs involved in the firmware distribution failure; XML tag is MeterIDs even though some valid Device types are not meters.Non-Sensitive

Response codes (16.2.1.3)

DUIS response codes applicable to this alert

E20