DCC Alert

N34 — Cancellation of “Future Dated (DSP)” requests because of CHF Decommission

SMETS applicability: All

Trigger & context

When and why this alert fires

Event
Cancellation of all “Future Dated (DSP)” Services not yet submitted to the CHF and its associated GPF
Trigger
Upon successful completion of Service Request 8.3 Decommission Device for a Device
Recipient(s)
All applicable Future Dated (DSP) Request senders
SMETS applicability
All
Payload DUIS applicability
>= 1.0

DUIS delivery

Wrapper and field names

Wrapper element
DCCAlertMessage
Alert code field
DCCAlertCode
Payload field
DCCAlert
Throttling supported
Yes

Payload structure (16.2.1)

CommandFailuresr:CommandFailure

This payload element is shared across multiple DCC alert codes:N3N7N10N11N12N13N14N15N33N34N35N36N38N41N53

A Command has failed.

FieldTypeMandatoryDescriptionSensitivity
CommandRequestIDsr:RequestIDTypeYesRequest ID of the Command that failed.Non-Sensitive
DSPScheduleIDsr:scheduleIDNoFor DSP Scheduled Commands, ID of the DSP Schedule associated to the Command.Non-Sensitive
DeviceIDsr:EUIYesDevice ID for which the Command failed.Non-Sensitive

Response codes (16.2.1.3)

DUIS response codes applicable to this alert

I0

DUIS XSD version: >= 1.0