DCC Alert

N35 — Cancellation of “Future Dated (DSP)” requests because of Device Withdrawal

SMETS applicability: SMETS2 or later

Trigger & context

When and why this alert fires

Event
Cancellation of all “Future Dated (DSP)” Services not yet submitted to the Device6
Trigger
Upon successful completion of Service Request 8.5 Service Opt Out for a Device
Recipient(s)
All applicable Future Dated (DSP) Request senders
SMETS applicability
SMETS2 or later
Payload DUIS applicability
>= 1.0

DUIS delivery

Wrapper and field names

Wrapper element
DCCAlertMessage
Alert code field
DCCAlertCode
Payload field
DCCAlert
Throttling supported
Yes

Payload structure (16.2.1)

CommandFailuresr:CommandFailure

This payload element is shared across multiple DCC alert codes:N3N7N10N11N12N13N14N15N33N34N35N36N38N41N53

A Command has failed.

FieldTypeMandatoryDescriptionSensitivity
CommandRequestIDsr:RequestIDTypeYesRequest ID of the Command that failed.Non-Sensitive
DSPScheduleIDsr:scheduleIDNoFor DSP Scheduled Commands, ID of the DSP Schedule associated to the Command.Non-Sensitive
DeviceIDsr:EUIYesDevice ID for which the Command failed.Non-Sensitive

Response codes (16.2.1.3)

DUIS response codes applicable to this alert

I0

DUIS XSD version: >= 1.0