Trigger & context
When and why this alert fires
- Event
- Device’s Firmware Version is unknown (not in the CPL) D evice’s Firmware Version updated in the Smart Metering Inventory and Device Status set to ‘Suspended’
- Trigger
- Upon successful completion of Service Request 11.2 Read Firmware Version where the target Device is ESME, GSME, HCALCS, PPMID or CHF and the Firmware Version returned by the Device is different from that in the SMI and it doesn’t match an entry on the CPL OR Upon completion of Service Request 11.3 Activate Firmware where the Firmware Version returned by the Device is different from that in the SMI and it doesn’t match an entry on the CPL OR Future Dated Firmware Activation Alert (Alert Code 0x8F66 or 0x8F67 and Message Code 0x00CA) received by the DCC Data Systems where the Firmware Version returned by the Device is different from that in the SMI and it doesn’t match an entry on the CPL OR PPMID Firmware Activation Alert (Device Alert Code 0x8F8B) received by the DCC Systems where the Firmware Version returned by the Device is different from that in the SMI and it doesn’t match an entry on the CPL
- Recipient(s)
- Responsible EIS Responsible GIS
- SMETS applicability
- All
- Introduced in DUIS
- 2.0
- Payload DUIS applicability
- >= 2.0