DCC Alert

N52 — GSME Firmware Version Mismatch

SMETS applicability: All

Trigger & context

When and why this alert fires

Event
GSME’s Firmware Version returned by the GPF is different from that in the Smart Metering Inventory GSME’s Firmware Version not updated in the Smart Metering Inventory
Trigger
Upon successful completion of Service Request 11.2 Read Firmware Version where the target Device is GPF and the GSME Firmware Version returned by the GPF is different from that in the SMI
Recipient(s)
Responsible GIS
SMETS applicability
All
Introduced in DUIS
2.0
Payload DUIS applicability
>= 2.0

DUIS delivery

Wrapper and field names

Wrapper element
DCCAlertMessage
Alert code field
DCCAlertCode
Payload field
DCCAlert
Throttling supported
Yes

Payload structure (16.2.1)

FirmwareVersionMismatchsr:FirmwareVersionMismatch

This payload element is shared across multiple DCC alert codes:N49N50N51N52

Firmware Version mismatch between SMI and value returned by Device / GPF.

FieldTypeMandatoryDescriptionSensitivity
DeviceIDsr:EUIYesDevice ID with a Firmware Version mismatch between SMI and the Device.Non-Sensitive
DeviceTypesr:DeviceTypeYesDevice type with a Firmware Version mismatch.Non-Sensitive
FirmwareVersionSMIxs:string minLength=1 maxLength=8YesFirmware Version in SMI, as applicable to N49-N52, format XXXXXXXX.Non-Sensitive
FirmwareVersionDevicexs:string minLength=1 maxLength=8YesFirmware Version returned by the Device/GPF, as applicable to N49-N52, format XXXXXXXX unless unknown.Non-Sensitive

Response codes (16.2.1.3)

DUIS response codes applicable to this alert

I0

DUIS XSD version: >= 2.0