Business Processes / 3.2.3

No WAN Installation – GSME Credit

14 primary steps · 1 associated steps

StepSRVDescriptionComment
18.11Update HAN Device LogChange in InstallCode field attribute – DUIS3.0 onwards.
28.13Return Local Command ResponseUpdate SR 8.11 response to DCC
38.13Return Local Command ResponseDevice Alert 0X8F12
3.1Wait For DCC Alert N24/N25If N24 received then go to next step
46.21Request Handover Of DCC Controlled DeviceGSME - Supplier Certificate
56.21Request Handover Of DCC Controlled DeviceGPF - Supplier Certificate
61.1.1Update Import Tariff (Primary Element)
76.8Update Device Configuration (Billing Calendar)
88.13Return Local Command ResponseUpdate SR 6.8 response to DCC
98.7.2Join Service (Non-Critical)Join GPF with GSME. If SR is not sent, the GPF would not mirror GSME data. (TS1671)
108.13Return Local Command ResponseUpdate SR 8.7.2 response to DCC
118.13Return Local Command ResponseDevice Alert 0x8071
121.5Update Meter Balance‘Adjust’
136.21Request Handover Of DCC Controlled DeviceNetwork Operator Certificate on GPF
146.15.1Update Security CredentialsUpdate load controller certs on ESME if APC is present.