SMETS1 Supporting Requirements

1.5 · Update Meter Balance

Section 18 requirements joined to the Device Model Variations to Equivalent Steps Matrix.

How the data is joined

Source model and interpretation

The matrix identifies one or more Section 18 references in column B and one or more SRVs in column C. Where a row lists several references, this page uses the PDF section owner to select the reference for the current SRV. A single reference explicitly listed with several SRVs is treated as applying to each of those SRVs. Only profiles marked x are displayed below; the complete source status remains preserved in the generated data.

x · Affectedn/a · Not applicablep · PPMID onlyText · Conditional noteBlank · No variation recorded
Requirements source
SEC-Appendix-AM-SMETS1-Supporting-Requirements-v17.0.pdf · v17.0 · Section 18, PDF pages56–110
Matrix source
SEC-Appendix-AM-Annex-A-Device-Model-Variations-to-Equivalent-Steps-Matrix-v12.4.xlsx · v12.4 · worksheetDMVES

Annex A matrix

Device-model applicability

Select one or more values in each filter. Values within a filter are matched as OR; different filters are combined as AND against the same device combination. Options that cannot match the selections in the other filters are disabled automatically.

Manufacturer
Device Type
Model
Firmware

18.3a · source row 42

Update Meter Balance

18.3a · Where the target SMETS1 ESME or SMETS1 GSME does not support Adjust Meter Balance when Payment Mode is Credit Mode and the Device is in Credit Mode (with their SMETS meanings), the S1SP shall return a SMETS1 Response indicating failure.

Affected device and firmware combinations

Manufacturer
Honeywell
Device Type
GSME
Model
BK-G4E EI2
Firmware
0.10.94
Manufacturer
Itron
Device Type
GSME
Model
RF1 Sv ZB
Firmware
012-00.292/10D6
Manufacturer
Landis+Gyr
Device Type
GSME
Model
G470
Firmware
xxxxxxxxx

18.3b · source row 43

Update Meter Balance

18.3b · Where the target SMETS1 ESME or SMETS1 GSME has no function to ResetMeterBalance (with its DUIS meaning) in Credit Mode and the Payment Mode (with its SMETS1 meaning) is Credit and the Service Request specifies a ResetMeterBalance (with its DUIS meaning) the S1SP shall create a SMETS1 Response indicating failure.

Affected device and firmware combinations

Manufacturer
Honeywell
Device Type
ESME
Model
AS300P
Firmware
ASP 04.04.01-55497
Manufacturer
Honeywell
Device Type
GSME
Model
BK-G4E EI2
Firmware
0.10.94
Manufacturer
Honeywell
Device Type
ESME
Model
AS300P
Firmware
ASP 04.04.01-60250
Manufacturer
Itron
Device Type
GSME
Model
RF1 Sv ZB
Firmware
012-00.292/10D6
Manufacturer
Landis+Gyr
Device Type
GSME
Model
G470
Firmware
xxxxxxxxx

18.3c · source row 44

Update Meter Balance

18.3c · Where the target SMETS1 ESME or SMETS1 GSME may apply Payment based Debt Recovery (with its SMETS1 meaning) when a positive adjustment is made to the Meter Balance, the increase in the Meter Balance resulting from this Service Request may be correspondingly less than the adjustment specified.

Affected device and firmware combinations

Manufacturer
Aclara
Device Type
ESME
Model
SGM1311
Firmware
03.03.06
Manufacturer
Secure Meters
Device Type
ESME
Model
Liberty 100 (with aux)
Firmware
P4X9G01

18.3d · source row 45

Update Meter Balance

18.3d · Where the target SMETS1 ESME or SMETS1 GSME does not support negative adjustments to the ESME Meter Balance/ GSME PrepaymentMode Meter Balance (with their DUIS and SMETS1 meanings) if the result of applying those adjustments would have been either to change the Meter Balance from a negative value to a more negative value or from a non-negative value to a negative value, then the S1SP shall create a SMETS1 Response indicating failure should such a Service Request be received.

Affected device and firmware combinations

Manufacturer
Secure Meters
Device Type
ESME
Model
Liberty 100 (with aux)
Firmware
P4X9G01
Manufacturer
Secure Meters
Device Type
GSME
Model
EG4v11
Firmware
Q4X2G0E

18.3e · source row 46

Update Meter Balance

18.3e · Where the target SMETS1 ESME or SMETS1 GSME processes a positive adjustment to the GSME PrepaymentMode Meter Balance (with their DUIS and SMETS1 meanings) then the Device will, in addition to adjusting the Meter Balance (with its SMETS1 meaning), first apply that adjustment to the Accumulated Debt Register if it is greater than zero, second, if the accumulated Debt Register is zero, or is reduced to zero, apply any remaining adjustment to the Emergency Credit Balance until it reaches the Emergency Credit Limit.

Affected device and firmware combinations

Manufacturer
Secure Meters
Device Type
ESME
Model
Liberty 100 (with aux)
Firmware
P4X9G01
Manufacturer
Secure Meters
Device Type
GSME
Model
EG4v11
Firmware
Q4X2G0E

18.3f · source row 47

Update Meter Balance

18.3f · Where the SMETS1 GSME does not support the setting of Meter Balance (with its SMETS1 meaning) to greater than £20,000 then the S1SP shall, where it receives a Service Request that would result in a Meter Balance of greater than £20,000, return a SMETS1 Response indicating failure.

Affected device and firmware combinations

Manufacturer
Landis+Gyr
Device Type
GSME
Model
G470
Firmware
xxxxxxxxx

18.3g · source row 48

Update Meter Balance

18.3g · The target SMETS1 ESME and SMETS1 GSME applies the adjustment in the following order: (i) recovery of Payment-based Debt of an amount defined by Debt Recovery per Payment from the Payment Debt Register subject to the Debt Recovery Rate Cap; (ii) recovery of debt accumulated in the Accumulated Debt Register; (iii) increasing the meter balance until it reaches the non-disablement threshold; (iv) repayment of Emergency Credit activated and used by Consumer; and (v) adding remaining credit (the credit after deduction of i, ii, iii and iv above) to the Meter Balance.

Affected device and firmware combinations

Manufacturer
Landis+Gyr
Device Type
ESME
Model
E470
Firmware
xxxxxxx
Manufacturer
Landis+Gyr
Device Type
GSME
Model
G470
Firmware
xxxxxxxxx

18.3h · source row 49

Update Meter Balance

18.3h · Where the target SMETS1 ESME does not support a zero value for AdjustMeterValue (with its DUIS meaning) then where such a Service Request is received, the S1SP shall create a SMETS1 Response indicating failure.

Affected device and firmware combinations

Manufacturer
Landis+Gyr
Device Type
ESME
Model
E470
Firmware
xxxxxxx