SMETS1 Supporting Requirements

2.2 · Top Up Device

Section 18 requirements joined to the Device Model Variations to Equivalent Steps Matrix.

How the data is joined

Source model and interpretation

The matrix identifies one or more Section 18 references in column B and one or more SRVs in column C. Where a row lists several references, this page uses the PDF section owner to select the reference for the current SRV. A single reference explicitly listed with several SRVs is treated as applying to each of those SRVs. Only profiles marked x are displayed below; the complete source status remains preserved in the generated data.

x · Affectedn/a · Not applicablep · PPMID onlyText · Conditional noteBlank · No variation recorded
Requirements source
SEC-Appendix-AM-SMETS1-Supporting-Requirements-v17.0.pdf · v17.0 · Section 18, PDF pages56–110
Matrix source
SEC-Appendix-AM-Annex-A-Device-Model-Variations-to-Equivalent-Steps-Matrix-v12.4.xlsx · v12.4 · worksheetDMVES

Annex A matrix

Device-model applicability

Select one or more values in each filter. Values within a filter are matched as OR; different filters are combined as AND against the same device combination. Options that cannot match the selections in the other filters are disabled automatically.

Manufacturer
Device Type
Model
Firmware

18.6a · source row 110

Top Up Device

18.6a · The target SMETS1 ESME and SMETS1 GSME applies the credit added in the following order: (i) recovery of Payment-based Debt of an amount defined by Debt Recovery per Payment from the Payment Debt Register subject to the Debt Recovery Rate Cap; (ii) recovery of debt accumulated in the Accumulated Debt Register; (iii) increasing the meter balance until it reaches the non-disablement threshold; (iv) repayment of Emergency Credit activated and used by Consumer; and (v) adding remaining credit (the credit after deduction of i, ii, iii and iv above) to the Meter Balance.

Affected device and firmware combinations

Manufacturer
Landis+Gyr
Device Type
ESME
Model
E470
Firmware
xxxxxxx
Manufacturer
Landis+Gyr
Device Type
GSME
Model
G470
Firmware
xxxxxxxxx

18.6b · source row 111

Top Up Device

18.6b · Where the target SMETS1 ESME or SMETS1 GSME only supports UTRN values (with its DUIS meaning) that represent positive integer multiples of 100, then the S1SP shall, where the Command Variant is 2 or 3, return a SMETS1 Alert indicating failure, unless the UTRN value provided represents a positive integer multiple of 100. For clarity, DUIS states in section 1.4.7.5 that “For SMETS1 Service Requests with a Command Variant value of 2 or 3, the UTRN data item shall contain a 20 digit string (each digit taking a value of 0-9) representing value in pence, using leading zeros as necessary to give a 20 digit length.”

Affected device and firmware combinations

Manufacturer
Landis+Gyr
Device Type
ESME
Model
E470
Firmware
xxxxxxx
Manufacturer
Landis+Gyr
Device Type
GSME
Model
G470
Firmware
xxxxxxxxx