Service Reference Variant

4.11.2 · Read Tariff (Secondary Element)

Service details

Identifiers, rules, and applicability

Service reference
4.11
Service Reference Variant
4.11.2
DUIS section
3.8.34
Command variants
1, 2, 3
DUIS possible responses
AcknowledgementService Response from Device - GBCSPayloadResponse to a Command for Local Delivery Request - LocalCommand Format
Critical
No
Sensitive response
No
Protection against replay
No
On demand
Yes
Future dated
No
DSP scheduled
No
DCC only
No
SMETS1 applicability
No
SAPC requirement
Not stated
DUIS applicability
3.0, 3.1, 4.0, 5.0, 5.1, 5.2, 5.3

Cross-specification evidence

SMETS/CHTS to GBCS Mapping

This section shows the SMETS and CHTS attributes that can be read or written by the identified GBCS Use Case. Command requirements are shown separately from the mapped attributes.

ECS24b3 attributes0x00BDESME
SpecificationItemReferenceDescription
SMETSSecondary Tariff TOU Price Matrix [INFO]5.13.1.1A 1 x 4 matrix containing Prices for Time-of-use Pricing Tariffs relating to Supply via the secondary measuring element of the Electricity Meter.
SMETSTariff Switching Table [INFO]5.13.1.2Tariff Switching Table(5.7.4.48) in Part A shall not apply to ESME.
SMETSSecondary Active Tariff Price [INFO]5.13.2.9The Price currently active for Consumption via the secondary measuring element of the Electricity Meter.

Specific Errors

Response codes and descriptions

No specific validation is defined for this SRV.

GBCS Use Case

Use cases, device coverage, and applicability

Use Case / Message Code
ECS24b0x00BD
DUIS Applicability
v3.0 – v5.3
GBCS Applicability
v1.0 – v4.3
GBCS Criticality
Non-Critical
Sensitive Response
No
Future Dated
No
ResponseESMENot always GBT
SMETS1 Applicable
No
Eligible Roles
EISOUESME

Message Patterns & Examples

Pattern explorer

Open Message Patterns →