SMETS1 Supporting Requirements

4.6.1 · Retrieve Import Daily Read Log

Section 18 requirements joined to the Device Model Variations to Equivalent Steps Matrix.

How the data is joined

Source model and interpretation

The matrix identifies one or more Section 18 references in column B and one or more SRVs in column C. Where a row lists several references, this page uses the PDF section owner to select the reference for the current SRV. A single reference explicitly listed with several SRVs is treated as applying to each of those SRVs. Only profiles marked x are displayed below; the complete source status remains preserved in the generated data.

x · Affectedn/a · Not applicablep · PPMID onlyText · Conditional noteBlank · No variation recorded
Requirements source
SEC-Appendix-AM-SMETS1-Supporting-Requirements-v17.0.pdf · v17.0 · Section 18, PDF pages56–110
Matrix source
SEC-Appendix-AM-Annex-A-Device-Model-Variations-to-Equivalent-Steps-Matrix-v12.4.xlsx · v12.4 · worksheetDMVES

Annex A matrix

Device-model applicability

Select one or more values in each filter. Values within a filter are matched as OR; different filters are combined as AND against the same device combination. Options that cannot match the selections in the other filters are disabled automatically.

Manufacturer
Device Type
Model
Firmware

18.21a · source row 178

Retrieve Import Daily Read Log

18.21a · The provisions of Clauses 18.17 18.17(b) to 18.17 18.17(c) apply to this Service Request

Affected device and firmware combinations

Manufacturer
Honeywell
Device Type
ESME
Model
AS300P
Firmware
ASP 04.04.01-55497
Manufacturer
Honeywell
Device Type
ESME
Model
AS300P
Firmware
ASP 04.04.01-60250
Manufacturer
Itron
Device Type
GSME
Model
RF1 Sv ZB
Firmware
012-00.292/10D6
Manufacturer
Landis+Gyr
Device Type
GSME
Model
G470
Firmware
xxxxxxxxx

18.21b · source row 179

Retrieve Import Daily Read Log

18.21b · Where the target SMETS1 ESME or SMETS1 GSME may record such Daily Read Log (with its SMETS1 meaning) entries after midnight UTC then the SMETS1 Response may contain Timestamps (with their MMC meanings) reflecting the delayed recording.

Affected device and firmware combinations

Manufacturer
Secure Meters
Device Type
ESME
Model
Liberty 100 (with aux)
Firmware
P4X9G01
Manufacturer
Secure Meters
Device Type
GSME
Model
EG4v11
Firmware
Q4X2G0E

18.21c · source row 180

Retrieve Import Daily Read Log

18.21c · Where the SMETS1 GSME takes snapshots at 23:00 UTC during the period of British Summer Time then any log entries for such periods will have such a corresponding 23:00 UTC timestamp.

Affected device and firmware combinations

Manufacturer
Landis+Gyr
Device Type
GSME
Model
G470
Firmware
xxxxxxxxx

18.21d · source row 181

Retrieve Import Daily Read Log

18.21d · The provision of Clause 18.17(e) apply to this Service Request.

Affected device and firmware combinations

Manufacturer
Landis+Gyr
Device Type
GSME
Model
G470
Firmware
xxxxxxxxx

18.21e · source row 182

Retrieve Import Daily Read Log

18.21e · Where the target SMETS1 GSME resets the TariffBlockCounterMatrix (with their Message Mapping Catalogue meaning) before taking a Billing Calendar (with its SMETS1 meaning) snapshot and this is the last day of the billing period then: (i) Outside of British Summer Time the TariffBlockCounterMatrix values (with their MMC meaning) will all be 0; and (ii) During British Summer Time the TariffBlockCounterMatrix will only reflect consumption for 23 of the 24 hours of the day.

Affected device and firmware combinations

Manufacturer
Landis+Gyr
Device Type
GSME
Model
G470
Firmware
xxxxxxxxx

18.21f · source row 183

Retrieve Import Daily Read Log

18.21f · Where, pursuant to Clause 18.21(c), the time period specified in the Service Request includes the Timestamp of 00:00 of the current day and the current day is within BST and the Device processes the Service Request before 23:00 UTC, the target SMETS1 GSME will return a LogEntry with a Timestamp of 00:00 that will reflect the same consumption as recorded where the Timestamp is 23:00 (with their MMC meanings).

Affected device and firmware combinations

Manufacturer
Landis+Gyr
Device Type
GSME
Model
G470
Firmware
xxxxxxxxx

18.21g · source row 184

Retrieve Import Daily Read Log

18.21g · The provisions of Clause 18.17(j) also apply to this Service Request.

Affected device and firmware combinations

Manufacturer
Landis+Gyr
Device Type
ESME
Model
E470
Firmware
xxxxxxx

18.21h · source row 185

Retrieve Import Daily Read Log

18.21h · The provisions of Clause 18.17(m) also apply to this Service Request.

Affected device and firmware combinations

Manufacturer
Honeywell
Device Type
ESME
Model
AS300P
Firmware
ASP 04.04.01-55497
Manufacturer
Honeywell
Device Type
ESME
Model
AS300P
Firmware
ASP 04.04.01-60250

18.21i · source row 186

Retrieve Import Daily Read Log

18.21i · The provisions of Clause 18.17(n) also apply to this Service Request.

Affected device and firmware combinations

Manufacturer
Honeywell
Device Type
ESME
Model
AS300P
Firmware
ASP 04.04.01-55497
Manufacturer
Honeywell
Device Type
ESME
Model
AS300P
Firmware
ASP 04.04.01-60250
Manufacturer
Itron
Device Type
ESME
Model
EM425-UK
Firmware
03.00.03.46/53.17

18.21j · source row 187

Retrieve Import Daily Read Log

18.21j · The provisions of Clause 18.17(o) also apply to this Service Request.

Affected device and firmware combinations

Manufacturer
Honeywell
Device Type
GSME
Model
BK-G4E EI2
Firmware
0.10.94