Service Reference Variant

6.12 · Update Device Configuration (Instantaneous Power Threshold)

Service details

Identifiers, rules, and applicability

Service reference
6.12
Service Reference Variant
6.12
DUIS section
3.8.62
Command variants
1, 2, 3
DUIS possible responses
AcknowledgementService Response from Device - GBCSPayloadResponse to a Command for Local Delivery Request - LocalCommand FormatCountersigned SMETS1 Response
Critical
No
Sensitive response
No
Protection against replay
No
On demand
Yes
Future dated
DSP
DSP scheduled
No
DCC only
No
SMETS1 applicability
Yes
SAPC requirement
Optional
DUIS applicability
3.0, 3.1, 4.0, 5.0, 5.1, 5.2, 5.3

Cross-specification evidence

SMETS/CHTS to GBCS Mapping

This section shows the SMETS and CHTS attributes that can be read or written by the identified GBCS Use Case. Command requirements are shown separately from the mapped attributes.

ECS342 attributes0x0047ESME
SpecificationItemReferenceDescription
SMETSLow Medium Power Threshold [INFO]5.7.4.24A value in kW defining the threshold between an indicative low and medium Active Power Import [INFO](5.7.5.4) level.
SMETSMedium High Power Threshold [INFO]5.7.4.29A value in kW defining the threshold between an indicative medium and high Active Power Import [INFO](5.7.5.4) level.

Specific Errors

Response codes and descriptions

No specific validation is defined for this SRV.

GBCS Use Case

Use cases, device coverage, and applicability

Use Case / Message Code
ECS340x0047
DUIS Applicability
v3.0 – v5.3
GBCS Applicability
v1.0 – v4.3
GBCS Criticality
Non-Critical
Sensitive Response
No
Future Dated
DSP
GBT
No
SMETS1 Applicable
Yes
Eligible Roles
EISESME

DUIS Service Definition

Data items and DCC processing

Request data items

Table 176: UpdateDeviceConfigurationInstantaneousPowerThreshold (sr:UpdateDeviceConfigurationInstantaneousPowerThreshold) data items
Data ItemDescription / Valid SetTypeMandatoryDefaultUnits
ExecutionDateTimeA User shall only add this Data Item to the Service Request where they require the Service Request to be executed at a future date and time. The UTC date and time the User requires the Command to be executed on the Device Date-time in the future that is either <= current date + 30 days or the date = ‘3000-12-31T00:00:00Z’xs:dateTimeNoNoneUTC Date-Time
LowMediumPowerThresholdA value in W defining the threshold between an indicative low and medium Active Power Import levelxs: unsignedIntYesNoneW
MediumHighPowerThresholdA value in W defining the threshold between an indicative medium and high Active Power Import levelxs: unsignedIntrYesNoneW

Message Patterns & Examples

Pattern explorer

Open Message Patterns →

SMETS1 Supporting Requirements

Device-model variations and equivalent steps

Review the Section 18 requirements and their applicability across the documented manufacturer, Device Type, model, and firmware profiles.

Open S1SR Requirements →