18.32a · source row 243
Read Device Configuration (Billing Calendar)
18.32a · Where the target SMETS1 ESME or SMETS1 GSME does not support a time other than midnight UTC in its Billing Calendar (with its SMETS1 meaning), the time values in BillingTime and BillingPeriodStart (with their Message Mapping Catalogue meanings) shall be midnight UTC.
Affected device and firmware combinations
- Manufacturer
- Aclara
- Device Type
- ESME
- Model
- SGM1311
- Firmware
- 03.03.06
- Manufacturer
- Aclara
- Device Type
- ESME
- Model
- SGM1312
- Firmware
- 03.03.06
- Manufacturer
- Aclara
- Device Type
- ESME
- Model
- SGM1312
- Firmware
- 00:03:03:0A