Service Reference Variant

6.20.1 · Set Device Configuration (Import MPxN)

Service details

Identifiers, rules, and applicability

Service reference
6.2
Service Reference Variant
6.20.1
DUIS section
3.8.72
Command variants
1, 2, 3
DUIS possible responses
AcknowledgementService Response from Device - GBCSPayloadResponse to a Command for Local Delivery Request - LocalCommand Format
Critical
No
Sensitive response
No
Protection against replay
Yes
On demand
Yes
Future dated
DSP
DSP scheduled
No
DCC only
No
SMETS1 applicability
No
SAPC requirement
Optional
DUIS applicability
3.0, 3.1, 4.0, 5.0, 5.1, 5.2, 5.3

Cross-specification evidence

SMETS/CHTS to GBCS Mapping

This section shows the SMETS and CHTS attributes that can be read or written by the identified GBCS Use Case. Command requirements are shown separately from the mapped attributes.

ECS39a1 attribute0x004CESME
SpecificationItemReferenceDescription
SMETSMeter Point Administration Numbers (MPAN) [INFO]5.7.4.28The reference numbers identifying an electricity metering point for Import and Export.
GCS411 attribute0x0087GSME
SpecificationItemReferenceDescription
SMETSMeter Point Reference Number (MPRN)4.6.4.19The reference number identifying a gas metering point.

Specific Errors

Response codes and descriptions

No specific validation is defined for this SRV.

GBCS Use Case

Use cases, device coverage, and applicability

Use Case / Message Code
ECS39a0x004C
DUIS Applicability
v3.0 – v5.3
GBCS Applicability
v1.0 – v4.3
GBCS Criticality
Non-Critical
Sensitive Response
No
Future Dated
DSP
GBT
No
SMETS1 Applicable
No
Eligible Roles
EISESME
Use Case / Message Code
GCS410x0087
DUIS Applicability
v3.0 – v5.3
GBCS Applicability
v1.0 – v4.3
GBCS Criticality
Non-Critical
Sensitive Response
No
Future Dated
DSP
GBT
No
SMETS1 Applicable
No
Eligible Roles
GISGSME

DUIS Service Definition

Data items and DCC processing

Request data items

Table 193: SetDeviceConfigurationImportMPxN (sr:SetDeviceConfigurationImportMPxN) data items
Data ItemDescription / Valid SetTypeMandatoryDefaultUnits
ExecutionDateTimeA User shall only add this Data Item to the Service Request where they require the Service Request to be executed at a future date and time. The UTC date and time the User requires the Command to be executed on the Device Date-time in the future that is either <= current date + 30 days or the date = ‘3000-12-31T00:00:00Z’xs:dateTimeNoNoneUTC Date-Time
ImportMPANsFor Electricity Smart Meters, the Primary Element Import MPAN and, for Twin Element Meters, also the Secondary Element Import MPANsr:ImportMPANsElectricity Smart Meter: Yes Otherwise: N/ANoneNone
ImportMPRNFor Gas Smart Meters, the reference number identifying a gas metering pointsr:MPRN Restriction of xs:string (minLength = 1, maxLength = 10)Gas Smart Meter: Yes Otherwise: N/ANoneNone
Table 194: ImportMPANs (sr:ImportMPANs) data items
Data ItemDescription / Valid SetTypeMandatoryDefaultUnits
ImportMPANThe reference number identifying an import electricity metering pointsr:MPAN Restriction of xs:string (minLength = 13 maxLength = 13)YesNoneN/A
SecondaryImportMPANThe reference number identifying the secondary import electricity metering pointsr:MPAN Restriction of xs:string (minLength = 13, maxLength = 13)Electricity Smart Meter (non Twin Element) N/A Electricity Smart Meter (Twin Element) NoNoneN/A

Message Patterns & Examples

Pattern explorer

Open Message Patterns →