Service Reference Variant

6.22 · Configure Alert Behaviour

Service details

Identifiers, rules, and applicability

Service reference
6.22
Service Reference Variant
6.22
DUIS section
3.8.75
Command variants
1, 2, 3
DUIS possible responses
AcknowledgementService Response from Device - GBCSPayloadResponse to a Command for Local Delivery Request - LocalCommand Format
Critical
No
Sensitive response
No
Protection against replay
No
On demand
Yes
Future dated
No
DSP scheduled
No
DCC only
No
SMETS1 applicability
No
SAPC requirement
Optional
DUIS applicability
3.0, 3.1, 4.0, 5.0, 5.1, 5.2, 5.3

Cross-specification evidence

SMETS/CHTS to GBCS Mapping

This section shows the SMETS and CHTS attributes that can be read or written by the identified GBCS Use Case. Command requirements are shown separately from the mapped attributes.

ECS25a1 attribute0x00ACESME
SpecificationItemReferenceDescription
SMETSAlerts Configuration Settings5.7.4.1Settings to control whether to generate and send an Alert.
ECS25a11 attribute0x00EAESME
SpecificationItemReferenceDescription
SMETSAlerts Configuration Settings5.7.4.1Settings to control whether to generate and send an Alert.
ECS25a21 attribute0x00EBESME
SpecificationItemReferenceDescription
SMETSEvents Configuration Settings5.7.4.51Settings to control, for each Alert described in this Section 5 and for each event which this Section 5 requires the ESME to be capable of logging in the Event Log(5.7.5.16) or Power Event Log(5.7.5.25) which is not a Critical Event, whether an Alarm is sounded and whether an Event Log entry or Power event log entry is created.
ECS25a31 attribute0x00ECESME
SpecificationItemReferenceDescription
SMETSEvents Configuration Settings5.7.4.51Settings to control, for each Alert described in this Section 5 and for each event which this Section 5 requires the ESME to be capable of logging in the Event Log(5.7.5.16) or Power Event Log(5.7.5.25) which is not a Critical Event, whether an Alarm is sounded and whether an Event Log entry or Power event log entry is created.
ECS25b1 attribute0x00B0ESME
SpecificationItemReferenceDescription
SMETSAlerts Configuration Settings5.7.4.1Settings to control whether to generate and send an Alert.
ECS25b31 attribute0x00EDESME
SpecificationItemReferenceDescription
SMETSEvents Configuration Settings5.7.4.51Settings to control, for each Alert described in this Section 5 and for each event which this Section 5 requires the ESME to be capable of logging in the Event Log(5.7.5.16) or Power Event Log(5.7.5.25) which is not a Critical Event, whether an Alarm is sounded and whether an Event Log entry or Power event log entry is created.
GCS201 attribute0x00ADGSME
SpecificationItemReferenceDescription
SMETSAlerts Configuration Settings4.6.4.1Settings to control whether to generate and send an Alert.

Specific Errors

Response codes and descriptions

Response CodeResponse Code Description
E062201
The Service Request is invalid. The combination of User Role and Alert Code Configuration contents is incorrect OR at least one Alert configuration is not present.
E062202
The combination of Electricity Smart Meter Variant and Service Request contents is invalid
E062203
The GBCS version that pertains to the Device Model recorded in the SMI for this Device, does not support the chosen features of this Service Request

Source: DUIS 3.8.75.3

GBCS Use Case

Use cases, device coverage, and applicability

Use Case / Message Code
ECS25a0x00AC
DUIS Applicability
v3.0 – v5.3
GBCS Applicability
v1.0 – v4.3
GBCS Criticality
Non-Critical
Sensitive Response
No
Future Dated
No
GBT
No
SMETS1 Applicable
No
Eligible Roles
EISESME
Use Case / Message Code
ECS25a10x00EA
DUIS Applicability
v3.0 – v5.3
GBCS Applicability
v2.0 – v4.3
GBCS Criticality
Non-Critical
Sensitive Response
No
Future Dated
No
GBT
No
SMETS1 Applicable
No
Eligible Roles
EISESME
Use Case / Message Code
ECS25a20x00EB
DUIS Applicability
v3.0 – v5.3
GBCS Applicability
v2.0 – v4.3
GBCS Criticality
Non-Critical
Sensitive Response
No
Future Dated
No
GBT
No
SMETS1 Applicable
No
Eligible Roles
EISESME
Use Case / Message Code
ECS25a30x00EC
DUIS Applicability
v3.0 – v5.3
GBCS Applicability
v2.0 – v4.3
GBCS Criticality
Non-Critical
Sensitive Response
No
Future Dated
No
GBT
No
SMETS1 Applicable
No
Eligible Roles
EISESME
Use Case / Message Code
ECS25b0x00B0
DUIS Applicability
v3.0 – v5.3
GBCS Applicability
v1.0 – v4.3
GBCS Criticality
Non-Critical
Sensitive Response
No
Future Dated
No
GBT
No
SMETS1 Applicable
No
Eligible Roles
ENOESME
Use Case / Message Code
ECS25b30x00ED
DUIS Applicability
v3.0 – v5.3
GBCS Applicability
v2.0 – v4.3
GBCS Criticality
Non-Critical
Sensitive Response
No
Future Dated
No
GBT
No
SMETS1 Applicable
No
Eligible Roles
ENOESME
Use Case / Message Code
GCS200x00AD
DUIS Applicability
v3.0 – v5.3
GBCS Applicability
v1.0 – v4.3
GBCS Criticality
Non-Critical
Sensitive Response
No
Future Dated
No
CommandGSMENot always GBT
SMETS1 Applicable
No
Eligible Roles
GISGSME

DUIS Service Definition

Data items and DCC processing

Request data items

Table 198: ConfigureAlertBehaviour (sr:ConfigureAlertBehaviour) data items
Data ItemDescription / Valid SetTypeMandatoryDefaultUnits
ElectricitySupplierAlertsThe configuration settings for WAN Alerts which the IS can configure on the ESMEsr:ElectricitySupplierAlerts See Table 199IS and ESME where the GBCS Version is Version 1.0: Yes IS and ESME where the GBCS Version is Version 2.0: Optional Otherwise: N/ANoneN/A
ElectricitySupplierHANAlertSettingsThe configuration settings for HAN Alerts which the IS can configure on the ESME. ElectricitySupplierHANAlertSettings is only supported on Devices with a Device Model recorded in the Smart Metering Inventory that pertains to GBCS version 2.0 according to the entry for that Device Model in the Central Products Listsr:ElectricitySupplierAlerts See Table 199IS and ESME where the where the GBCS Version is Version 2.0: Optional Otherwise: N/ANoneN/A
ElectricitySupplierAlarmSettingsThe configuration settings for audible Alarms (associated to WAN Alerts, HAN Alerts and / or events recorded in the Event Log) which the IS can configure on the ESME. ElectricitySupplierAlarmSettings is only supported on Devices with a Device Model recorded in the Smart Metering Inventory that pertains to GBCS version 2.0 according to the entry for that Device Model in the Central Products Listsr:ElectricitySupplierAlerts See Table 199IS and ESME where the GBCS Version is Version 2.0: Optional Otherwise: N/ANoneN/A
ElectricitySupplierLoggi ngSettingsThe configuration settings for logging Events in the Event Logs, which the IS can configure on the ESME. ElectricitySupplierLoggingSettings is only supported on Devices with a Device Model recorded in the Smart Metering Inventory that pertains to GBCS version 2.0 according to the entry for that Device Model in the Central Products Listsr:ElectricitySupplierAlerts See Table 199IS and ESME where the where the GBCS Version is Version 2.0: Optional Otherwise: N/ANoneN/A
ElectricityNetworkOperatorAlertsThe configuration settings for WAN Alerts which the ED can configure on the ESME.sr:ElectricityNetworkOperatorAlerts See Table 200ED and ESME where the GBCS Version is Version 1.0: Yes ED and ESME where the GBCS Version is Version 2.0: Optional Otherwise: N/ANoneN/A
ElectricityNetworkOperatorLoggingSettingsThe configuration settings for logging Events in the Power Event Log, which the ED can configure on the ESME. ElectricityNetworkOperatorLoggingSettings is only supported on Devices with a Device Model recorded in the Smart Metering Inventory that pertains to GBCS version 2.0 according to the entry for that Device Model in the Central Products Listsr:ElectricityNetworkOperatorAlerts See Table 200ED and ESME where the GBCS Version is Version 2.0: Optional Otherwise: N/ANoneN/A
GasSupplierAlertsThe configuration settings for WAN Alerts which the GS can configure on the GSME. GasSupplierAlerts is only supported on Devices with a Device Model recorded in the Smart Metering Inventory that pertains to GBCS version 1.0 according to the entry for that Device Model in the Central Products Listsr:SupplierGSME See Table 201GS and GSME where the GBCS Version is Version 1.0: Yes Otherwise: N/ANoneN/A
GasSupplierAlertEventSettingsThe configuration settings for WAN Alerts, HAN Alerts, logging of Events in the Event Log and / or audible Alarms (associated to WAN Alerts, HAN Alerts and / or events recorded in the Event Log) which the GS can configure on the GSME. GasSupplierAlertEventSettings is only supported on Devices with a Device Model recorded in the Smart Metering Inventory that pertains to GBCS version 2.0 according to the entry for that Device Model in the Central Products Listsr: SupplierGSMEAlertsEvents See Table 202GS and GSME where the GBCS Version is Version 2.0: Yes Otherwise: N/ANoneN/A
Table 199: ElectricitySupplierAlerts (sr:ElectricitySupplierAlerts) data items
Data ItemDescription / Valid SetTypeMandatoryDefaultUnits
SupplierESMECommonA set of Event / Alert Codes (as defined by GBCS) for which WAN Alert, HAN Alert, audible Alarm or logging of Events to the Event Log behaviours that are applicable to both Single and Poly Phase meters are to be configured.sr:SupplierESMECommon See Table 204No (If included, at least 1 Alert Code must be configured)NoneN/A
SupplierESMEPolyPhaseA set of Event / Alert Codes (as defined by GBCS) for which WAN Alert, HAN Alert, audible Alarm or logging of Events to the Event Log behaviours that are only applicable to Poly Phase meters are to be configured.sr:SupplierESMEPolyPhase See Table 204No (If included, at least 1 Alert Code must be configured)NoneN/A
Table 200: ElectricityNetworkOperatorAlerts (sr:ElectricityNetworkOperatorAlerts) data items
Data ItemDescription / Valid SetTypeMandatoryDefaultUnits
NetworkOperatorESMECommonA set of Event / Alert Codes (as defined by GBCS) for which WAN Alert or logging of Events to the Power Event Log behaviours that are applicable to both Single and Poly Phase meters are to be configured.sr:NetworkOperatorESMECommon See Table 204No (If included, at least 1 Alert Code must be configured)NoneN/A
NetworkOperatorESMESinglePhaseA set of Event / Alert Codes (as defined by GBCS) for which WAN Alert or logging of Events to the Power Event Log behaviours that are only applicable to Single Phase meters are to be configured.sr:NetworkOperatorESMESinglePhase See Table 204No (If included, at least 1 Alert Code must be configured)NoneN/A
NetworkOperatorESMEPolyPhaseA set of Event / Alert Codes (as defined by GBCS) for which WAN Alert or logging of Events to the Power Event Log behaviours that are only applicable to Poly Phase meters are to be configured.sr:NetworkOperatorESMEPolyPhase See Table 204No (If included, at least 1 Alert Code must be configured)NoneN/A
Table 201: GasSupplierAlerts (sr:SupplierGSME) data items
Data ItemDescription / Valid SetTypeMandatoryDefaultUnits
GasSupplierAlertsA set of Event / Alert Codes (as defined by GBCS) for which WAN Alert behaviours that are applicable to a Gas Smart Meter are to be configured.sr:SupplierGSME See Table 204No (If included, at least 1 Alert Code must be configured)NoneN/A
Table 202: GasSupplierAlertEventSettings (sr:SupplierGSMEAlertsEvents) data items
Data ItemDescription / Valid SetTypeMandatoryDefaultUnits
GasSupplierAlertEventSettingsA set of Event / Alert Codes(as defined by GBCS) with configurable WAN Alert, HAN Alert, Alarm and / or Event Logging that are applicable to a Gas Smart Meter are to be configured.sr:WANHANEventLogAlarm See Table 203No (If included, at least 1 Alert Code must be configured)NoneN/A
Table 203: WANHANEventLogAlarm (sr:WANHANEventLogAlarm) data items
Data ItemDescription / Valid SetTypeMandatoryDefaultUnits
XML Tag name is the GBCS Alert Code without the leading zero. e.g. x81AA (for Alert 0x81AA)Applicable to each Event / Alert Code with configurable WAN Alert, HAN Alert, Event Log and Alarm on the GSME. For each of these alerts, e.g. 0x81AA, the WAN Alert, HAN Alert, the Event Log and the Alarm have to be configured at the same time, but their setting (enable / disable) can be differentSee Table 204NoNoneN/A
Table 204: Alert Type (sr:EnableDisableAlert) data items
Data ItemDescription / Valid SetTypeMandatoryDefaultUnits
AlertCode XML Tag name is the GBCS Alert Code without the leading zero. e.g. x81ADEach of the following elements contain a sequence of GBCS Alert Codes; SupplierESMECommon SupplierESMEPolyPhase NetworkOperatorESMECommon NetworkOperatorESMESinglePhase NetworkOperatorESMEPolyPhase GasSupplierAlerts GasSupplierAlertEventSettings See clause 16.2 of GBCS for the definition of these codes. Each Device Alert may be enabled (turned on) or disabled (turned off), if a Device Alert is not reconfigured as part of this Service Request then its configuration state is unchanged. Valid set; Enable Disablesr:EnableDisableAlert (Restriction of xs:string (Enumeration))NoNoneN/A

Message Patterns & Examples

Pattern explorer

Open Message Patterns →