SMETS1 Supporting Requirements

6.8 · Update Device Configuration (Billing Calendar)

Section 18 requirements joined to the Device Model Variations to Equivalent Steps Matrix.

How the data is joined

Source model and interpretation

The matrix identifies one or more Section 18 references in column B and one or more SRVs in column C. Where a row lists several references, this page uses the PDF section owner to select the reference for the current SRV. A single reference explicitly listed with several SRVs is treated as applying to each of those SRVs. Only profiles marked x are displayed below; the complete source status remains preserved in the generated data.

x · Affectedn/a · Not applicablep · PPMID onlyText · Conditional noteBlank · No variation recorded
Requirements source
SEC-Appendix-AM-SMETS1-Supporting-Requirements-v17.0.pdf · v17.0 · Section 18, PDF pages56–110
Matrix source
SEC-Appendix-AM-Annex-A-Device-Model-Variations-to-Equivalent-Steps-Matrix-v12.4.xlsx · v12.4 · worksheetDMVES

Annex A matrix

Device-model applicability

Select one or more values in each filter. Values within a filter are matched as OR; different filters are combined as AND against the same device combination. Options that cannot match the selections in the other filters are disabled automatically.

Manufacturer
Device Type
Model
Firmware

18.42a · source row 273

Update Device Configuration (Billing Calendar)

18.42a · Where the target SMETS1 ESME or SMETS1 GSME does not support a time other than midnight UTC in its Billing Calendar (with its SMETS1 meaning), the S1SP shall ignore the time elements of the BillingTime or BillingPeriodStart (with their DUIS meanings) and shall set the time in the Billing Calendar (with its SMETS1 meaning) to midnight UTC.

Affected device and firmware combinations

Manufacturer
Aclara
Device Type
ESME
Model
SGM1311
Firmware
03.03.06
Manufacturer
Aclara
Device Type
ESME
Model
SGM1312
Firmware
03.03.06
Manufacturer
Aclara
Device Type
ESME
Model
SGM1312
Firmware
00:03:03:0A
Manufacturer
Secure Meters
Device Type
ESME
Model
Liberty 100 (with aux)
Firmware
P4X9G01
Manufacturer
Secure Meters
Device Type
GSME
Model
EG4v11
Firmware
Q4X2G0E
Manufacturer
Landis+Gyr
Device Type
ESME
Model
E470
Firmware
xxxxxxx
Manufacturer
Landis+Gyr
Device Type
GSME
Model
G470
Firmware
xxxxxxxxx

18.42b · source row 274

Update Device Configuration (Billing Calendar)

18.42b · Where the target SMETS1 ESME or SMETS1 GSME does not support a time resolution greater than minutes in its Billing Calendar (with its SMETS1 meaning), the S1SP shall ignore the seconds part of the time in the BillingTime or BillingPeriodStart (with their DUIS meanings) and shall set the seconds part of the time in the Billing Calendar (with its SMETS1 meaning) to zero.

Affected device and firmware combinations

Manufacturer
Honeywell
Device Type
ESME
Model
AS300P
Firmware
ASP 04.04.01-55497
Manufacturer
Honeywell
Device Type
GSME
Model
BK-G4E EI2
Firmware
0.10.94
Manufacturer
Honeywell
Device Type
ESME
Model
AS300P
Firmware
ASP 04.04.01-60250

18.42c · source row 275

Update Device Configuration (Billing Calendar)

18.42c · Where the target SMETS1 GSME does not support the Billing Calendar (with its SMETS1 meaning), the S1SP shall create a SMETS1 Response indicating failure.

Affected device and firmware combinations

Manufacturer
Aclara
Device Type
GSME
Model
G4SZV
Firmware
04.22.16
Manufacturer
Aclara
Device Type
GSME
Model
G4SZV
Firmware
04.24.16

18.42d · source row 276

Update Device Configuration (Billing Calendar)

18.42d · Where the target SMETS1 GSME only supports a Billing Calendar timetable of either (1) midnight daily, (2) weekly at midnight on Monday or (3) monthly at midnight on the first of the month (with its SMETS1 meaning) and the Service Request specifies a GasBillingCalendar (with its DUIS meaning) with a timetable that is other than one of those options, the S1SP shall create a SMETS1 Response indicating failure.

Affected device and firmware combinations

Manufacturer
Itron
Device Type
GSME
Model
RF1 Sv ZB
Firmware
012-00.292/10D6

18.42e · source row 277

Update Device Configuration (Billing Calendar)

18.42e · Where the target SMETS1 ESME requires a Billing Calendar (with its SMETS1 meaning) with a start date in the past, and where a Periodicity of Yearly, SixMonthly or Quarterly (with their DUIS meanings) is specified in the Service Request, the S1SP shall derive, using the S1SP Time, a DayOf Month and BillingPeriodStartMonth (with their DUIS meanings) from the corresponding fields in the Service Request to ensure they refer to a dateTime (with its DUIS meaning) which is earlier than today, according to the S1SP Time.

Affected device and firmware combinations

Manufacturer
Itron
Device Type
GSME
Model
RF1 Sv ZB
Firmware
012-00.292/10D6
Manufacturer
Secure Meters
Device Type
ESME
Model
Liberty 100 (with aux)
Firmware
P4X9G01

18.42f · source row 278

Update Device Configuration (Billing Calendar)

18.42f · Where the SMETS1 GSME does not support BillingPeriodStart (with its DUIS meaning) in the future and the S1SP receives a Service Request where, according to the S1SPs current time, the BillingPeriodStart is in the future, then the S1SP shall return a SMETS1 Response indicating failure and undertake no further processing.

Affected device and firmware combinations

Manufacturer
Secure Meters
Device Type
GSME
Model
EG4v11
Firmware
Q4X2G0E

18.42g · source row 279

Update Device Configuration (Billing Calendar)

18.42g · Where the SMETS1 GSME does not support BillingPeriodStart (with its DUIS meaning) in the future and the S1SP receives a Service Request where, according to the S1SPs current time, the BillingPeriodStart is in the future, then the S1SP shall: (i) derive, using the S1SP Time, a BillingPeriodStart by taking the specified BillingPeriodStart and decreasing it by the minimum number of periods specified in the Periodicity (with its DUIS meaning) in order to derive a date-time in the past; and (ii) configure the Device with the resulting BillingPeriodStart, recognising that the time element will be ignored by the Device, in terms of when resulting Billing Data Log (with its SMETS1 meaning) entries are created. Rather the Device shall create such entries at 23:59:59 on the dates prior to the dates specified by the derived BillingPeriodStart and Periodicity. Additionally, the Device will immediately create a BillingDataLog entry which would be returned in a subsequent Retrieve Change Of Mode / Tariff Triggered Billing Data Log (SRV 4.4.2) Service Request which covers this period.

Affected device and firmware combinations

Manufacturer
Landis+Gyr
Device Type
GSME
Model
G470
Firmware
xxxxxxxxx

18.42h · source row 280

Update Device Configuration (Billing Calendar)

18.42h · Where the target SMETS1 ESME receives Service Request with BillingPeriodStart (with its DUIS meaning) in the future then SMETS1 ESME updates the billing period correctly but the associated SMETS1 PPMID will not reflect the EMSE update and associated data.

Affected device and firmware combinations

Manufacturer
Itron
Device Type
ESME
Model
EM425-UK
Firmware