SMETS1 Supporting Requirements

8.11 · Update HAN Device Log

Section 18 requirements joined to the Device Model Variations to Equivalent Steps Matrix.

How the data is joined

Source model and interpretation

The matrix identifies one or more Section 18 references in column B and one or more SRVs in column C. Where a row lists several references, this page uses the PDF section owner to select the reference for the current SRV. A single reference explicitly listed with several SRVs is treated as applying to each of those SRVs. Only profiles marked x are displayed below; the complete source status remains preserved in the generated data.

x · Affectedn/a · Not applicablep · PPMID onlyText · Conditional noteBlank · No variation recorded
Requirements source
SEC-Appendix-AM-SMETS1-Supporting-Requirements-v17.0.pdf · v17.0 · Section 18, PDF pages56–110
Matrix source
SEC-Appendix-AM-Annex-A-Device-Model-Variations-to-Equivalent-Steps-Matrix-v12.4.xlsx · v12.4 · worksheetDMVES

Annex A matrix

Device-model applicability

Select one or more values in each filter. Values within a filter are matched as OR; different filters are combined as AND against the same device combination. Options that cannot match the selections in the other filters are disabled automatically.

Manufacturer
Device Type
Model
Firmware

18.62a · source row 305

Update HAN Device Log

18.62a · Where the SMETS1 CHF only supports a JoinTimePeriod (with its DUIS meaning) of up to 255 and the JoinTimePeriod (with its DUIS meaning) specified is greater than 255, the S1SP shall treat the JoinTimePeriod (with its DUIS meaning) as if it were 255.

Affected device and firmware combinations

Manufacturer
Aclara
Device Type
CHF
Model
SGC1311
Firmware
03.03.13
Manufacturer
Landis+Gyr
Device Type
CHF
Model
SEAP2000
Firmware
xxxxxxxxx
Manufacturer
Landis+Gyr
Device Type
CHF
Model
SEAP2001
Firmware
xxxxxxxxx

18.62b · source row 306

Update HAN Device Log

18.62b · Where the SMETS1 CHF requires a Cyclic Redundancy Check (CRC) (with the meaning given by the ZigBee Alliance) to be present in the Install Code (with the meaning given by the ZigBee Alliance), the S1SP shall calculate the CRC from the InstallCode (with its DUIS meaning) and append to the InstallCode sending the resulting value to the Device.

Affected device and firmware combinations

Manufacturer
Aclara
Device Type
CHF
Model
SGC1311
Firmware
03.03.13
Manufacturer
Honeywell
Device Type
CHF
Model
AMR110R
Firmware
03.07.09 (49) Rev 09
Manufacturer
Honeywell
Device Type
CHF
Model
AMR110R
Firmware
03.07.09 (53) - REV09
Manufacturer
Itron
Device Type
CHF
Model
EK410-UK
Firmware
00.03.00.33/53.37
Manufacturer
Itron
Device Type
CHF
Model
EK410-UK
Firmware
03.36.53.37

18.62c · source row 307

Update HAN Device Log

18.62c · Where the RequestType (with its DUIS meaning) is Remove, and the target Device is a SMETS1 ESME, S1SP shall create a SMETS1 Response indicating failure and shall take no further action.

Affected device and firmware combinations

Manufacturer
Aclara
Device Type
ESME
Model
SGM1311
Firmware
03.03.06
Manufacturer
Aclara
Device Type
ESME
Model
SGM1312
Firmware
03.03.06
Manufacturer
Aclara
Device Type
ESME
Model
SGM1312
Firmware
00:03:03:0A
Manufacturer
Honeywell
Device Type
ESME
Model
AS300P
Firmware
ASP 04.04.01-55497
Manufacturer
Honeywell
Device Type
ESME
Model
AS300P
Firmware
ASP 04.04.01-60250
Manufacturer
Itron
Device Type
ESME
Model
EM425-UK
Firmware
03.00.03.46/53.17
Manufacturer
Secure Meters
Device Type
ESME
Model
Liberty 100 (with aux)
Firmware
P4X9G01

18.62d · source row 308

Update HAN Device Log

18.62d · Where the SMETS1 CHF only supports a JoinTimePeriod (with its DUIS meaning) in whole minutes then the S1SP shall round down the provided JoinTimePeriod (with its DUIS meaning) to the nearest whole number of minutes and instruct the Device accordingly.

Affected device and firmware combinations

Manufacturer
Secure Meters
Device Type
CHF
Model
Skyline i-510
Firmware
HUB3FOX

18.62e · source row 309

Update HAN Device Log

18.62e · Where the SMETS1 CHF only supports a JoinTimePeriod (with its DUIS meaning) in whole minutes and the JoinTimePeriod (with its DUIS meaning) specified is less than 60 seconds, the S1SP shall return a SMETS1 Response indicating failure and take no further action.

Affected device and firmware combinations

Manufacturer
Secure Meters
Device Type
CHF
Model
Skyline i-510
Firmware
HUB3FOX

18.62f · source row 310

Update HAN Device Log

18.62f · Not Used.

Affected device and firmware combinations

No affected device and firmware combination is marked for this clause.