Service Reference Variant

8.14.1 · Communications Hub Status Update- Install Success

Service details

Identifiers, rules, and applicability

Service reference
8.14
Service Reference Variant
8.14.1
DUIS section
3.8.118
Command variants
8
DUIS possible responses
Acknowledgement
Critical
No
Sensitive response
No
Protection against replay
No
On demand
No
Future dated
No
DSP scheduled
No
DCC only
Yes
SMETS1 applicability
No
SAPC requirement
Not stated
DUIS applicability
3.0, 3.1, 4.0, 5.0, 5.1, 5.2, 5.3

Specific Errors

Response codes and descriptions

Response CodeResponse Code Description
E081401
The Device Type of the Device being notified is not CHF
E081402
The install date & time supplied is a future date
W081401
The CHF SMI Status is not ‘Commissioned’. The change in logistical status of the CHF will be processed by the DCC, but no commissioned status is set according to information from the SM WAN rather than Service Requests. If the CHF SMI Status is not ‘Commissioned’ this suggests that the CHF Device has not been installed successfully.

Source: DUIS 3.8.118.3

GBCS Use Case

Use cases, device coverage, and applicability

Instruction
CommunicationsHubStatusUpdate-InstallSuccess
DUIS Applicability
v3.0 – v5.3
GBCS Applicability
DCC Only
GBCS Criticality
N/A
Sensitive Response
No
Future Dated
No
GBT
No
SMETS1 Applicable
No
Eligible Roles
EISGISDSP

DUIS Service Definition

Data items and DCC processing

Request data items

Table 249: CHFInstallSuccessSMWAN (sr:CHFInstallSuccessSMWAN) data items
Data ItemDescription / ValuesTypeMandatoryDefaultUnits
DeviceIDThe device ID of the Communications Hub successfully installed (CHF)sr:EUI (See clause 3.10.1.3)YesNoneN/A
CHFInstallTypeValid set in this context from the enumeration is: New CHF Install Replacement CHF Installsr:CHFInstallType (Restriction of xs:string (Enumeration))YesNoneN/A
InstallDateTimeAn optional field to record the date and time that the CHF was successfully installedxs:dateTimeNoNoneUTC Date-Time
UserRefIDAn optional field to record User reference for activity or engineer jobsr:UserRefID (Restriction of xs:string (maxLength = 25))NoNoneN/A
MPxNThe reference number identifying an electricity or a gas metering point. For dual fuel installs this value can be populated with either reference number.sr:MPxN (Restriction of xs:string (minLength = 1, maxLength = 13))YesNoneN/A
GISDataGPS coordinates. Where address information is not available, alternative location data may be providedsr:GISData (Restriction of xs:string (maxLength = 25))NoNoneN/A
AerialInstallIndication of whether external aerial installed Valid set: true falsexs:booleanYesNoneN/A
CHFLocationInstallation location within Consumer Premise as further defined through Communications Hubs Support Materials and Installer Training Plans Valid set: Outside Premises Indoors on external wall Deep indoors Basement or Cellarsr:CHFLocation (Restriction of xs:string (Enumeration))YesNoneN/A
AdditionalInformationAn optional field to record any specific User information of Communications Hub installation details or activityRestriction of xs:string (maxLength = 200)NoNoneN/A