Service Reference Variant

8.6 · Service Opt In

Service details

Identifiers, rules, and applicability

Service reference
8.6
Service Reference Variant
8.6
DUIS section
3.8.108
Command variants
8
DUIS possible responses
Response to a Non-Device Service Request
Critical
No
Sensitive response
No
Protection against replay
No
On demand
No
Future dated
No
DSP scheduled
No
DCC only
Yes
SMETS1 applicability
No
SAPC requirement
Not stated
DUIS applicability
3.0, 3.1, 4.0, 5.0, 5.1, 5.2, 5.3

Specific Errors

Response codes and descriptions

Response CodeResponse Code Description
E080601
The Opt In Date is not a date in the future
E080602
The Device Type is not correct
E080604
The Device Status is not ‘Pending’
E080606
The Device Type is invalid
E080607
The User is not the registered organisation of any of the MPxNs in the Service Request

Source: DUIS 3.8.108.3

GBCS Use Case

Use cases, device coverage, and applicability

Instruction
ServiceOptIn
DUIS Applicability
v3.0 – v5.3
GBCS Applicability
DCC Only
GBCS Criticality
N/A
Sensitive Response
No
Future Dated
No
GBT
No
SMETS1 Applicable
No
Eligible Roles
None stated

DUIS Service Definition

Data items and DCC processing

Request data items

Table 236: ServiceOptIn (sr:ServiceOptIn) data items
Data ItemDescription / ValuesTypeMandatoryDefaultUnits
DeviceIDA unique ID for the devicesr:EUI (See clause 3.10.1.3)YesNoneN/A
DeviceTypeThe type of device. Valid set in this context from the enumeration set is; ESME GSME HCALCS PPMID CHF GPFsr:DeviceType (Restriction of xs:string (Enumeration))YesNoneN/A
MPxNsMPxNs to be associated to the Device once Opted Insr:MeterMPxNsYesNoneN/A
OptInDateUTC Date from which the device is planned to enter into DCC services Valid set:Valid date in the futurexs:dateYesNoneUTC Date
Table 237: MPxNs (sr:MeterMPxNs OptIn) data items
Data ItemDescription / ValuesTypeMandatoryDefaultUnits
ImportMPxNThe reference number identifying an Import electricity or a gas metering point.sr:ImportMPxN (Restriction of xs:string (minLength = 1, maxLength = 13))YesNoneN/A
SecondaryImportMPANThe reference number identifying a Twin Element Import electricity secondary metering point.sr:MPAN (Restriction of xs:string (minLength = 13, maxLength = 13))Twin Element ESME: No Otherwise: N/ANoneN/A
ExportMPANThe reference number identifying an Export electricity metering point.sr:MPAN (Restriction of xs:string (minLength = 13, maxLength = 13))Export ESME: No Otherwise: N/ANoneN/A

Response data items

Table 238: DSPOptin (sr:DSPOptin) data items
Data ItemDescription / ValuesTypeMandatoryDefaultUnits
DeviceIDA unique ID for the Devicesr:EUI (See clause 3.10.1.3)YesNoneN/A
DSPSecurityCredentialsDigitalSigningThe Digital Signing credentials to be placed by the Supplier (or Supplier’s SMSO) in the ‘ACB’ Remote Party Role, Key Usage digitalSignature on the Device so that communications via the DCC are possiblesr:Certificate (xs:base64Binary)DeviceType = PPMID,CHF: Yes Otherwise: N/ANoneN/A
DSPSecurityCredentialsKeyAgreementThe key agreement credentials to be placed by the Supplier (or Supplier’s SMSO) in the ‘ACB’ Remote Party Role Key Usage keyAgreement on the Device so that communications via the DCC are possiblesr:Certificate (xs:base64Binary)YesNoneN/A

Message Patterns & Examples

Pattern explorer

Open Message Patterns →