CHTS requirement clause

4.5.1.2 — Add CHF Device Security Credentials

6 technical records havebeen identified at this reference: 5 Section 20 items and 1 explicit clause reference. The links below describe documented interfaces and observable effects; they do not assert compliance with the source requirement.

CHFAlert touchpoint onlySRV touchpoint
5

Atomic items

Section 20 objects, attributes or methods at this source reference.

6

Documented touchpoints

Typed relationships supported by source mapping rows.

1

Linked SRVs

Unique retained services reached through exact control rows.

1

Linked alerts

Explicit requirement-to-alert references.

CHTS4.5.1.2 · item DeviceLog(CHF).methodInput: entryToBeAdded.credentialsType

DeviceLog(CHF) - entryToBeAdded credentialsType

SRV touchpoint

The type of installationCredentials supplied for a device to be added by the addEntry method

Object
DeviceLog(CHF)
Attribute / method
methodInput: entryToBeAdded.credentialsType
Interface disposition
E
Category
Method Input
Section 20 meaning
The type of installationCredentials supplied for a device to be added by the addEntry method

Documented touchpoints

Evidence:source paragraph 331, 332Section 20 row 1000

CHTS4.5.1.2 · item DeviceLog(CHF).methodInput: entryToBeAdded.deviceType

DeviceLog(CHF) - entryToBeAdded deviceType

SRV touchpoint

The type of the device to be added by the addEntry method. In addition to the values of this enumeration in the Blue Book, the CHF shall support the value 254 for GPF and interpret the value accordingly.

Object
DeviceLog(CHF)
Attribute / method
methodInput: entryToBeAdded.deviceType
Interface disposition
E
Category
Method Input
Section 20 meaning
The type of the device to be added by the addEntry method. In addition to the values of this enumeration in the Blue Book, the CHF shall support the value 254 for GPF and interpret the value accordingly.

Documented touchpoints

Evidence:source paragraph 331, 332Section 20 row 1001

CHTS4.5.1.2 · item DeviceLog(CHF).methodInput: entryToBeAdded.entityIdentifier

DeviceLog(CHF) - entryToBeAdded entityIdentifier

SRV touchpoint

Device Identifier of a device to be added by the addEntry method

Object
DeviceLog(CHF)
Attribute / method
methodInput: entryToBeAdded.entityIdentifier
Interface disposition
E
Category
Method Input
Section 20 meaning
Device Identifier of a device to be added by the addEntry method

Documented touchpoints

Evidence:source paragraph 331, 332Section 20 row 1002

CHTS4.5.1.2 · item DeviceLog(CHF).methodInput: entryToBeAdded.installationCredentials

DeviceLog(CHF) - entryToBeAdded installationCredentials

SRV touchpoint

Installation Credentials of the device to be added by the addEntry method

Object
DeviceLog(CHF)
Attribute / method
methodInput: entryToBeAdded.installationCredentials
Interface disposition
E
Category
Method Input
Section 20 meaning
Installation Credentials of the device to be added by the addEntry method

Documented touchpoints

Evidence:source paragraph 331, 332Section 20 row 1003

CHTS4.5.1.2 · item DeviceLog(CHF).method: addEntry

DeviceLog(CHF) - addEntry

SRV touchpoint

Add an entry to the Device Log using the details in entryToBeAdded

Object
DeviceLog(CHF)
Attribute / method
method: addEntry
Interface disposition
E
Category
Method
Section 20 meaning
Add an entry to the Device Log using the details in entryToBeAdded

Documented touchpoints

Evidence:source paragraph 331, 332Section 20 row 1004

CHTS4.5.1.2 · item clause.4.5.1.2

Add CHF Device Security Credentials

Alert touchpoint only

This source clause is explicitly referenced by the GBCS device alert table.

Category
Alert reference

Documented touchpoints

  • Alert touchpointCHF0x8F12CHF Device Log Changed
Evidence:source paragraph 331, 332

How to read this page

Evidence is kept at record level

A source clause can contain several separately mapped Section 20 items and an explicit alert reference. One item may be read by an SRV, another updated by a different service, and another have only an Alert or local-HAN path. Accordingly, the clause summary does not collapse those distinctions into a single covered or uncovered result.