SMETS requirement clause

4.5.3.6 — Adjust Meter Balance

5 technical records havebeen identified at this reference: 4 Section 20 items and 1 explicit clause reference. The links below describe documented interfaces and observable effects; they do not assert compliance with the source requirement.

GSMEAlert touchpoint onlySRV touchpoint
4

Atomic items

Section 20 objects, attributes or methods at this source reference.

5

Documented touchpoints

Typed relationships supported by source mapping rows.

1

Linked SRVs

Unique retained services reached through exact control rows.

1

Linked alerts

Explicit requirement-to-alert references.

SMETS4.5.3.6 · item MeterBalance.method: adjust

MeterBalance - adjust

SRV touchpoint

Applies the adjustment

Object
MeterBalance
Attribute / method
method: adjust
Interface disposition
E
Category
Method
Section 20 meaning
Applies the adjustment

Documented touchpoints

Evidence:source paragraph 535, 536Section 20 row 1045

SMETS4.5.3.6 · item MeterBalance.methodInput: adjustmentValue

MeterBalance - adjustmentValue

SRV touchpoint

The value of the adjustment

Object
MeterBalance
Attribute / method
methodInput: adjustmentValue
Interface disposition
E
Category
Method Input
Section 20 meaning
The value of the adjustment

Documented touchpoints

Evidence:source paragraph 535, 536Section 20 row 1047

SMETS4.5.3.6 · item MeterBalance.method: adjustCreditMode

MeterBalance - adjustCreditMode

SRV touchpoint

Applies the adjustment

Object
MeterBalance
Attribute / method
method: adjustCreditMode
Interface disposition
E
Category
Method
Section 20 meaning
Applies the adjustment

Documented touchpoints

Evidence:source paragraph 535, 536Section 20 row 1785

SMETS4.5.3.6 · item MeterBalance.methodInput: adjustmentValue

MeterBalance - adjustmentValue

SRV touchpoint

The amount by which the Meter Balance is to be adjusted

Object
MeterBalance
Attribute / method
methodInput: adjustmentValue
Interface disposition
E
Category
Method Input
Section 20 meaning
The amount by which the Meter Balance is to be adjusted

Documented touchpoints

Evidence:source paragraph 535, 536Section 20 row 1844

SMETS4.5.3.6 · item clause.4.5.3.6

Adjust Meter Balance

Alert touchpoint only

This source clause is explicitly referenced by the GBCS device alert table.

Category
Alert reference

Documented touchpoints

  • Alert touchpointGSME0x8F32Supply Armed
Evidence:source paragraph 535, 536

How to read this page

Evidence is kept at record level

A source clause can contain several separately mapped Section 20 items and an explicit alert reference. One item may be read by an SRV, another updated by a different service, and another have only an Alert or local-HAN path. Accordingly, the clause summary does not collapse those distinctions into a single covered or uncovered result.