Atomic items
Section 20 objects, attributes or methods at this source reference.
SMETS requirement clause
11 technical records havebeen identified at this reference: 11 Section 20 items and 0 explicit clause references. The links below describe documented interfaces and observable effects; they do not assert compliance with the source requirement.
Section 20 objects, attributes or methods at this source reference.
Typed relationships supported by source mapping rows.
Unique retained services reached through exact control rows.
Explicit requirement-to-alert references.
SMETS5.29.1.2 · item AuxiliaryController[n].method: controllerNumberAndCommandedState
See GBCS Section 7.3.6.1
AuxiliaryController[n]method: controllerNumberAndCommandedStateDocumented touchpoints
0x011EESMESRV 7.13SMETS5.29.1.2 · item AuxiliaryController[1].settingPeriodStartDateTime
The value in this field shall be the start date-time of the APC [1] Setting Period, ALCS[1] Setting Period or HCALCS[1] Setting Period, depending on whether Auxiliary Controller [1] is an APC, ALCS or HCALCS. It shall have no meaning if there is currently no such associated Auxiliary Controller. This field shall always be present where the 'controllerNumber' specified in the Command is 1 and shall never be present otherwise.
AuxiliaryController[1]settingPeriodStartDateTimeDocumented touchpoints
0x011EESMESRV 7.13SMETS5.29.1.2 · item AuxiliaryController[2].settingPeriodStartDateTime
The value in this field shall be the start date-time of the APC [2] Setting Period, ALCS[2] Setting Period or HCALCS[2] Setting Period, depending on whether Auxiliary Controller [2] is an APC, ALCS or HCALCS. It shall have no meaning if there is currently no such associated Auxiliary Controller. This field shall always be present where the 'controllerNumber' specified in the Command is 2 and shall never be present otherwise.
AuxiliaryController[2]settingPeriodStartDateTimeDocumented touchpoints
0x011EESMESRV 7.13SMETS5.29.1.2 · item AuxiliaryController[3].settingPeriodStartDateTime
The value in this field shall be the start date-time of the APC [3] Setting Period, ALCS[3] Setting Period or HCALCS[3] Setting Period, depending on whether Auxiliary Controller [3] is an APC, ALCS or HCALCS. It shall have no meaning if there is currently no such associated Auxiliary Controller. This field shall always be present where the 'controllerNumber' specified in the Command is 3 and shall never be present otherwise.
AuxiliaryController[3]settingPeriodStartDateTimeDocumented touchpoints
0x011EESMESRV 7.13SMETS5.29.1.2 · item AuxiliaryController[4].settingPeriodStartDateTime
The value in this field shall be the start date-time of the APC [4] Setting Period, ALCS[4] Setting Period or HCALCS[4] Setting Period, depending on whether Auxiliary Controller [4] is an APC, ALCS or HCALCS. It shall have no meaning if there is currently no such associated Auxiliary Controller. This field shall always be present where the 'controllerNumber' specified in the Command is 4 and shall never be present otherwise.
AuxiliaryController[4]settingPeriodStartDateTimeDocumented touchpoints
0x011EESMESRV 7.13SMETS5.29.1.2 · item AuxiliaryController[5].settingPeriodStartDateTime
The value in this field shall be the start date-time of the APC [5] Setting Period, ALCS[5] Setting Period or HCALCS[5] Setting Period, depending on whether Auxiliary Controller [5] is an APC, ALCS or HCALCS. It shall have no meaning if there is currently no such associated Auxiliary Controller. This field shall always be present where the 'controllerNumber' specified in the Command is 5 and shall never be present otherwise.
AuxiliaryController[5]settingPeriodStartDateTimeDocumented touchpoints
0x011EESMESRV 7.13SMETS5.29.1.2 · item AuxiliaryController[1].settingPeriodEndDateTime
The value in this field shall be the end date-time of the APC [1] Setting Period, ALCS[1] Setting Period or HCALCS[1] Setting Period, depending on whether Auxiliary Controller [1] is an APC, ALCS or HCALCS. It shall have no meaning if there is currently no such associated Auxiliary Controller. The Device shall, before updating this DLMS attribute, check that the settingPeriodEndDateTime is greater than the corresponding settingPeriodStartDateTime and is no more than 24 hours greater than the corresponding settingPeriodStartDateTime. If this check fails, the Device shall not update this DLMS attribute, and shall, in the Response, return corresponding Data-Access-Result / Action-Result values of other-reason for this and subsequent DLMS instructions in the Command. This field shall always be present where the 'controllerNumber' specified in the Command is 1 and shall never be present otherwise.
AuxiliaryController[1]settingPeriodEndDateTimeDocumented touchpoints
0x011EESMESRV 7.13SMETS5.29.1.2 · item AuxiliaryController[2].settingPeriodEndDateTime
The value in this field shall be the end date-time of the APC [2] Setting Period, ALCS[2] Setting Period or HCALCS[2] Setting Period, depending on whether Auxiliary Controller [2] is an APC, ALCS or HCALCS. It shall have no meaning if there is currently no such associated Auxiliary Controller. The Device shall, before updating this DLMS attribute, check that the settingPeriodEndDateTime is greater than the corresponding settingPeriodStartDateTime and is no more than 24 hours greater than the corresponding settingPeriodStartDateTime. If this check fails, the Device shall not update this DLMS attribute, and shall, in the Response, return corresponding Data-Access-Result / Action-Result values of other-reason for this and subsequent DLMS instructions in the Command. This field shall always be present where the 'controllerNumber' specified in the Command is 2 and shall never be present otherwise.
AuxiliaryController[2]settingPeriodEndDateTimeDocumented touchpoints
0x011EESMESRV 7.13SMETS5.29.1.2 · item AuxiliaryController[3].settingPeriodEndDateTime
The value in this field shall be the end date-time of the APC [3] Setting Period, ALCS[3] Setting Period or HCALCS[3] Setting Period, depending on whether Auxiliary Controller [3] is an APC, ALCS or HCALCS. It shall have no meaning if there is currently no such associated Auxiliary Controller. The Device shall, before updating this DLMS attribute, check that the settingPeriodEndDateTime is greater than the corresponding settingPeriodStartDateTime and is no more than 24 hours greater than the corresponding settingPeriodStartDateTime. If this check fails, the Device shall not update this DLMS attribute, and shall, in the Response, return corresponding Data-Access-Result / Action-Result values of other-reason for this and subsequent DLMS instructions in the Command. This field shall always be present where the 'controllerNumber' specified in the Command is 3 and shall never be present otherwise.
AuxiliaryController[3]settingPeriodEndDateTimeDocumented touchpoints
0x011EESMESRV 7.13SMETS5.29.1.2 · item AuxiliaryController[4].settingPeriodEndDateTime
The value in this field shall be the end date-time of the APC [4] Setting Period, ALCS[4] Setting Period or HCALCS[4] Setting Period, depending on whether Auxiliary Controller [4] is an APC, ALCS or HCALCS. It shall have no meaning if there is currently no such associated Auxiliary Controller. The Device shall, before updating this DLMS attribute, check that the settingPeriodEndDateTime is greater than the corresponding settingPeriodStartDateTime and is no more than 24 hours greater than the corresponding settingPeriodStartDateTime. If this check fails, the Device shall not update this DLMS attribute, and shall, in the Response, return corresponding Data-Access-Result / Action-Result values of other-reason for this and subsequent DLMS instructions in the Command. This field shall always be present where the 'controllerNumber' specified in the Command is 4 and shall never be present otherwise.
AuxiliaryController[4]settingPeriodEndDateTimeDocumented touchpoints
0x011EESMESRV 7.13SMETS5.29.1.2 · item AuxiliaryController[5].settingPeriodEndDateTime
The value in this field shall be the end date-time of the APC [5] Setting Period, ALCS[5] Setting Period or HCALCS[5] Setting Period, depending on whether Auxiliary Controller [5] is an APC, ALCS or HCALCS. It shall have no meaning if there is currently no such associated Auxiliary Controller. The Device shall, before updating this DLMS attribute, check that the settingPeriodEndDateTime is greater than the corresponding settingPeriodStartDateTime and is no more than 24 hours greater than the corresponding settingPeriodStartDateTime. If this check fails, the Device shall not update this DLMS attribute, and shall, in the Response, return corresponding Data-Access-Result / Action-Result values of other-reason for this and subsequent DLMS instructions in the Command. This field shall always be present where the 'controllerNumber' specified in the Command is 5 and shall never be present otherwise.
AuxiliaryController[5]settingPeriodEndDateTimeDocumented touchpoints
0x011EESMESRV 7.13How to read this page
A source clause can contain several separately mapped Section 20 items and an explicit alert reference. One item may be read by an SRV, another updated by a different service, and another have only an Alert or local-HAN path. Accordingly, the clause summary does not collapse those distinctions into a single covered or uncovered result.