GBCS 16.2 / 0x8F86

ECS101 Limit APC [n] Level Command processed

Alert Details

WAN: YUse Case Specific Alert StructureMandatedSee 7.2.9.1Pre-config: No

Cross-specification evidence

Technical requirement relationships

The source clauses below explicitly relate this alert to equipment behaviour. Confidence and evidence labels show how each relationship was established.

Alert touchpoint

2 clauses · 10 linked records
  • SMETS 5.29.1.1Exact evidence

    4 Section 20 items · 1 direct clause reference

    • Limit APC [n] Level
    • LimitAPC[n]LevelCommandProcessed - apcLimitPeriodEnd
    • + 3 more on the clause page
    ESMEECS101 · 0x0121 · ESME

    Evidence: gbcs_device_alert_extract_16.2.json · SEC-Schedule-8-GB-Companion-Specification-v4.4 - Section 20 - Message Mapping.xlsx · 16.2 · SMETS required objects · 5 source rows · 2 source references

  • SMETS 9.5.2.16Exact evidence

    4 Section 20 items · 1 direct clause reference

    • LimitAPC[n]LevelCommandProcessed - apcLimitPeriodStart
    • LimitAPC[n]LevelCommandProcessed - resultingLevel
    • + 3 more on the clause page
    ECS101 · 0x0121 · SAPCSAPC

    Evidence: SEC-Schedule-8-GB-Companion-Specification-v4.4 - Section 20 - Message Mapping.xlsx · gbcs_device_alert_extract_16.2.json · SMETS required objects · 16.2 · 5 source rows · 2 source references

Device Specific Details

See GBCS 7.2.9.1 for device-specific role assignments.

DUIS Annex 15 / 15.4.8

Device Alert payload structure

This alert carries additional structured payload defined by DUIS Annex 15 section 15.4.8, delivered inside ra:DeviceAlertContent asLimitAPCLevelCommandProcessedDeviceAlert.

Payload root
LimitAPCLevelCommandProcessedDeviceAlert
Payload type
LimitAPCLevelCommandProcessedDeviceAlert
Annex section
15.4.8 — Device Alert 0x8F86 Limit APC Level Command Processed

Message codes and device contexts

Message codeDevice contextMessage nameGBCS use case
0121Limit APC [n] Level Command ProcessedECS101

Payload fields

FieldTypeMandatoryUnitsDescriptionSensitivity
APCLimitPeriodStartxs:dateTimeYesStart of the APC Limit Period.Non-Sensitive
APCLimitPeriodEndxs:dateTimeYesEnd of the APC Limit Period.Non-Sensitive
AuxiliaryControllerNra:range_1_5 (xs:positiveInteger 1..5)YesIndex on the Device of the Auxiliary Controller to which this Device Alert applies. Device may have up to 5 Auxiliary Controllers; alert applies only to APC.Non-Sensitive
ResultingLevelra:AuxiliaryControllerLevel (xs:unsignedShort 0..100)YesLimit applied to the APC level of energy flow; 0 means no energy flow.Non-Sensitive