SMETS requirement clause
18 technical records havebeen identified at this reference: 17 Section 20 items and 1 explicit clause reference. The links below describe documented interfaces and observable effects; they do not assert compliance with the source requirement.
Section 20 objects, attributes or methods at this source reference.
Typed relationships supported by source mapping rows.
Unique retained services reached through exact control rows.
Explicit requirement-to-alert references.
SMETS5.29.1.1 · item LimitAPC[n]LevelCommandProcessed.apcLimitPeriodEnd
The date-time for the end of the APC [n] Limit Period, which its SMETS meaning
LimitAPC[n]LevelCommandProcessedapcLimitPeriodEndDocumented touchpoints
0x0121ESME0x8F86ECS101 Limit APC [n] Level Command processedSMETS5.29.1.1 · item LimitAPC[n]LevelCommandProcessed.apcLimitPeriodStart
The date-time for the start of the APC [n] Limit Period, which its SMETS meaning
LimitAPC[n]LevelCommandProcessedapcLimitPeriodStartDocumented touchpoints
0x0121ESME0x8F86ECS101 Limit APC [n] Level Command processedSMETS5.29.1.1 · item LimitAPC[n]LevelCommandProcessed.apcDirectionAndNumber
The most significant nibble of the octet shall be 0x1 (indicating output), or 0x2 (indicating input) and the least significant shall be 0xn, where n is the value in APC [n] and APC [n] is the APC affected, so a value between 1 and 5 inclusive.
LimitAPC[n]LevelCommandProcessedapcDirectionAndNumberDocumented touchpoints
0x0121ESME0x8F86ECS101 Limit APC [n] Level Command processedSMETS5.29.1.1 · item LimitAPC[n]LevelCommandProcessed.resultingLevel
The value 'p' where this Alert relates to output, or 'q' where it relates to input, where 'p' and 'q' are as per GBCS Section 7.3.6.1
LimitAPC[n]LevelCommandProcessedresultingLevelDocumented touchpoints
0x0121ESME0x8F86ECS101 Limit APC [n] Level Command processedSMETS5.29.1.1 · item LimitAPC[n]LevelEndedOrCancelled.apcDirectionAndNumber
The most significant nibble of the octet shall be 0x1 (indicating output) and the least significant shall be 0xn, where n is the value in APC [n] and APC [n] is the APC affected, so a value between 1 and 5 inclusive.
LimitAPC[n]LevelEndedOrCancelledapcDirectionAndNumberDocumented touchpoints
0x0122ESME0x8F87ECS102 Limit APC [n] Level ended or cancelledSMETS5.29.1.1 · item LimitAPC[n]LevelEndedOrCancelled.resultingLevel
The value 'p' where this Alert relates to output, or 'q' where it relates to input, where 'p' and 'q' are as per GBCS Section 7.3.6.1
LimitAPC[n]LevelEndedOrCancelledresultingLevelDocumented touchpoints
0x0122ESME0x8F87ECS102 Limit APC [n] Level ended or cancelledSMETS5.29.1.1 · item AuxiliaryProportionalController[1].limitPeriodStartDateTime
The value in this field shall be the start date-time of the APC [1] Limit Period if Auxiliary Controller [1] is an APC; otherwise it shall have no meaning. This field shall always be present where the 'controllerNumber' specified in the Command is 1 and shall never be present otherwise.
AuxiliaryProportionalController[1]limitPeriodStartDateTimeDocumented touchpoints
0x011FESMESRV 7.16SMETS5.29.1.1 · item AuxiliaryProportionalController[2].limitPeriodStartDateTime
The value in this field shall be the start date-time of the APC [2] Limit Period if Auxiliary Controller [2] is an APC; otherwise it shall have no meaning. This field shall always be present where the 'controllerNumber' specified in the Command is 2 and shall never be present otherwise.
AuxiliaryProportionalController[2]limitPeriodStartDateTimeDocumented touchpoints
0x011FESMESRV 7.16SMETS5.29.1.1 · item AuxiliaryProportionalController[3].limitPeriodStartDateTime
The value in this field shall be the start date-time of the APC [3] Limit Period if Auxiliary Controller [3] is an APC; otherwise it shall have no meaning. This field shall always be present where the 'controllerNumber' specified in the Command is 3 and shall never be present otherwise.
AuxiliaryProportionalController[3]limitPeriodStartDateTimeDocumented touchpoints
0x011FESMESRV 7.16SMETS5.29.1.1 · item AuxiliaryProportionalController[4].limitPeriodStartDateTime
The value in this field shall be the start date-time of the APC [4] Limit Period if Auxiliary Controller [4] is an APC; otherwise it shall have no meaning. This field shall always be present where the 'controllerNumber' specified in the Command is 4 and shall never be present otherwise.
AuxiliaryProportionalController[4]limitPeriodStartDateTimeDocumented touchpoints
0x011FESMESRV 7.16SMETS5.29.1.1 · item AuxiliaryProportionalController[5].limitPeriodStartDateTime
The value in this field shall be the start date-time of the APC [5] Limit Period if Auxiliary Controller [5] is an APC; otherwise it shall have no meaning. This field shall always be present where the 'controllerNumber' specified in the Command is 5 and shall never be present otherwise.
AuxiliaryProportionalController[5]limitPeriodStartDateTimeDocumented touchpoints
0x011FESMESRV 7.16SMETS5.29.1.1 · item AuxiliaryProportionalController[1].limitPeriodEndDateTime
The value in this field shall be the end date-time of the APC [1] Limit Period if Auxiliary Controller [1] is an APC; otherwise it shall have no meaning. The Device shall, before updating this DLMS attribute, check that the limitPeriodEndDateTime is greater than the corresponding limitPeriodStartDateTime and is no more than 24 hours greater than the corresponding limitPeriodStartDateTime. If this check fails, the Device shall not update this DLMS attribute, and shall, in the Response, return corresponding Data-Access-Result / Action-Result values of other-reason for this and subsequent DLMS instructions in the Command. This field shall always be present where the 'controllerNumber' specified in the Command is 1 and shall never be present otherwise.
AuxiliaryProportionalController[1]limitPeriodEndDateTimeDocumented touchpoints
0x011FESMESRV 7.16SMETS5.29.1.1 · item AuxiliaryProportionalController[2].limitPeriodEndDateTime
The value in this field shall be the end date-time of the APC [2] Limit Period if Auxiliary Controller [2] is an APC; otherwise it shall have no meaning. The Device shall, before updating this DLMS attribute, check that the limitPeriodEndDateTime is greater than the corresponding limitPeriodStartDateTime and is no more than 24 hours greater than the corresponding limitPeriodStartDateTime. If this check fails, the Device shall not update this DLMS attribute, and shall, in the Response, return corresponding Data-Access-Result / Action-Result values of other-reason for this and subsequent DLMS instructions in the Command. This field shall always be present where the 'controllerNumber' specified in the Command is 2 and shall never be present otherwise.
AuxiliaryProportionalController[2]limitPeriodEndDateTimeDocumented touchpoints
0x011FESMESRV 7.16SMETS5.29.1.1 · item AuxiliaryProportionalController[3].limitPeriodEndDateTime
The value in this field shall be the end date-time of the APC [3] Limit Period if Auxiliary Controller [3] is an APC; otherwise it shall have no meaning. The Device shall, before updating this DLMS attribute, check that the limitPeriodEndDateTime is greater than the corresponding limitPeriodStartDateTime and is no more than 24 hours greater than the corresponding limitPeriodStartDateTime. If this check fails, the Device shall not update this DLMS attribute, and shall, in the Response, return corresponding Data-Access-Result / Action-Result values of other-reason for this and subsequent DLMS instructions in the Command. This field shall always be present where the 'controllerNumber' specified in the Command is 3 and shall never be present otherwise.
AuxiliaryProportionalController[3]limitPeriodEndDateTimeDocumented touchpoints
0x011FESMESRV 7.16SMETS5.29.1.1 · item AuxiliaryProportionalController[4].limitPeriodEndDateTime
The value in this field shall be the end date-time of the APC [4] Limit Period if Auxiliary Controller [4] is an APC; otherwise it shall have no meaning. The Device shall, before updating this DLMS attribute, check that the limitPeriodEndDateTime is greater than the corresponding limitPeriodStartDateTime and is no more than 24 hours greater than the corresponding limitPeriodStartDateTime. If this check fails, the Device shall not update this DLMS attribute, and shall, in the Response, return corresponding Data-Access-Result / Action-Result values of other-reason for this and subsequent DLMS instructions in the Command. This field shall always be present where the 'controllerNumber' specified in the Command is 4 and shall never be present otherwise.
AuxiliaryProportionalController[4]limitPeriodEndDateTimeDocumented touchpoints
0x011FESMESRV 7.16SMETS5.29.1.1 · item AuxiliaryProportionalController[5].limitPeriodEndDateTime
The value in this field shall be the end date-time of the APC [5] Limit Period if Auxiliary Controller [5] is an APC; otherwise it shall have no meaning. The Device shall, before updating this DLMS attribute, check that the limitPeriodEndDateTime is greater than the corresponding limitPeriodStartDateTime and is no more than 24 hours greater than the corresponding limitPeriodStartDateTime. If this check fails, the Device shall not update this DLMS attribute, and shall, in the Response, return corresponding Data-Access-Result / Action-Result values of other-reason for this and subsequent DLMS instructions in the Command. This field shall always be present where the 'controllerNumber' specified in the Command is 5 and shall never be present otherwise.
AuxiliaryProportionalController[5]limitPeriodEndDateTimeDocumented touchpoints
0x011FESMESRV 7.16SMETS5.29.1.1 · item AuxiliaryProportionalController[n].method: controllerNumberAndCommandedState
See GBCS Section 7.3.6.1
AuxiliaryProportionalController[n]method: controllerNumberAndCommandedStateDocumented touchpoints
0x011FESMESRV 7.16SMETS5.29.1.1 · item clause.5.29.1.1
This source clause is explicitly referenced by the GBCS device alert table.
How to read this page
A source clause can contain several separately mapped Section 20 items and an explicit alert reference. One item may be read by an SRV, another updated by a different service, and another have only an Alert or local-HAN path. Accordingly, the clause summary does not collapse those distinctions into a single covered or uncovered result.