GBCS 16.2 / 0x8F87

ECS102 Limit APC [n] Level ended or cancelled

Alert Details

WAN: YUse Case Specific Alert StructureMandatedSee 7.2.9.1Pre-config: No

Cross-specification evidence

Technical requirement relationships

The source clauses below explicitly relate this alert to equipment behaviour. Confidence and evidence labels show how each relationship was established.

Alert touchpoint

2 clauses · 6 linked records
  • SMETS 5.29.1.1Exact evidence

    2 Section 20 items · 1 direct clause reference

    • LimitAPC[n]LevelEndedOrCancelled - resultingLevel
    • LimitAPC[n]LevelEndedOrCancelled - apcDirectionAndNumber
    • + 1 more on the clause page
    ECS102 · 0x0122 · ESMEESME

    Evidence: SEC-Schedule-8-GB-Companion-Specification-v4.4 - Section 20 - Message Mapping.xlsx · gbcs_device_alert_extract_16.2.json · SMETS required objects · 16.2 · 3 source rows · 2 source references

  • SMETS 9.5.2.16Exact evidence

    2 Section 20 items · 1 direct clause reference

    • LimitAPC[n]LevelEndedOrCancelled - resultingLevel
    • LimitAPC[n]LevelEndedOrCancelled - apcDirectionAndNumber
    • + 1 more on the clause page
    ECS102 · 0x0122 · SAPCSAPC

    Evidence: SEC-Schedule-8-GB-Companion-Specification-v4.4 - Section 20 - Message Mapping.xlsx · gbcs_device_alert_extract_16.2.json · SMETS required objects · 16.2 · 3 source rows · 2 source references

Device Specific Details

See GBCS 7.2.9.1 for device-specific role assignments.

DUIS Annex 15 / 15.4.9

Device Alert payload structure

This alert carries additional structured payload defined by DUIS Annex 15 section 15.4.9, delivered inside ra:DeviceAlertContent asLimitAPCLevelEndedDeviceAlert.

Payload root
LimitAPCLevelEndedDeviceAlert
Payload type
LimitAPCLevelEndedDeviceAlert
Annex section
15.4.9 — Device Alert 0x8F87 Limit APC Level Ended or Cancelled

Message codes and device contexts

Message codeDevice contextMessage nameGBCS use case
0122Limit APC [n] Level Ended or CancelledECS102

Payload fields

FieldTypeMandatoryUnitsDescriptionSensitivity
AuxiliaryControllerNra:range_1_5 (xs:positiveInteger 1..5)YesIndex on the Device of the Auxiliary Controller to which this Device Alert applies. Device may have up to 5 Auxiliary Controllers; alert applies only to APC.Non-Sensitive
ResultingLevelra:AuxiliaryControllerLevel (xs:unsignedShort 0..100)YesLevel of energy flow in the APC after the APC level limit period has ended. 100 means maximum energy flow and 0 means no energy flow.Non-Sensitive
InputFromControlledLoadra:NoTypeNoEmpty element. If present, limit direction is input energy from the controlled load; if absent, output energy to the controlled load.Non-Sensitive

Message Patterns and Examples

View the step-by-step alert delivery pattern — from device event through WAN transmission to Known Remote Party notification — with available XML examples.