SMETS1 Supporting Requirements

4.10 · Read Network Data

Section 18 requirements joined to the Device Model Variations to Equivalent Steps Matrix.

How the data is joined

Source model and interpretation

The matrix identifies one or more Section 18 references in column B and one or more SRVs in column C. Where a row lists several references, this page uses the PDF section owner to select the reference for the current SRV. A single reference explicitly listed with several SRVs is treated as applying to each of those SRVs. Only profiles marked x are displayed below; the complete source status remains preserved in the generated data.

x · Affectedn/a · Not applicablep · PPMID onlyText · Conditional noteBlank · No variation recorded
Requirements source
SEC-Appendix-AM-SMETS1-Supporting-Requirements-v17.0.pdf · v17.0 · Section 18, PDF pages56–110
Matrix source
SEC-Appendix-AM-Annex-A-Device-Model-Variations-to-Equivalent-Steps-Matrix-v12.4.xlsx · v12.4 · worksheetDMVES

Annex A matrix

Device-model applicability

Select one or more values in each filter. Values within a filter are matched as OR; different filters are combined as AND against the same device combination. Options that cannot match the selections in the other filters are disabled automatically.

Manufacturer
Device Type
Model
Firmware

18.25a · source row 205

Read Network Data

18.25a · Where the target SMETS1 ESME does not support the Average RMS Over Voltage Counter or Average RMS Under Voltage Counter operational data items (with their SMETS meanings), the S1SP shall omit the AvgRMSOverVoltageCounter and AvgRMSUnderVoltageCounter elements in the SMETS1 Response (with its Message Mapping Catalogue meaning).

Affected device and firmware combinations

Manufacturer
Aclara
Device Type
ESME
Model
SGM1311
Firmware
03.03.06
Manufacturer
Aclara
Device Type
ESME
Model
SGM1312
Firmware
03.03.06
Manufacturer
Aclara
Device Type
ESME
Model
SGM1312
Firmware
00:03:03:0A

18.25b · source row 206

Read Network Data

18.25b · Where the target SMETS1 GSME does not support the Network Data Log operational data item (with its SMETS meaning), the S1SP shall create a SMETS1 Response indicating failure.

Affected device and firmware combinations

Manufacturer
Aclara
Device Type
GSME
Model
G4SZV
Firmware
04.22.16
Manufacturer
Aclara
Device Type
GSME
Model
G4SZV
Firmware
04.24.16
Manufacturer
Honeywell
Device Type
GSME
Model
BK-G4E EI2
Firmware
0.10.94

18.25c · source row 207

Read Network Data

18.25c · Where the target SMETS1 GSME requires an Instruction to begin logging in to the Network Data Log operational data item (with its SMETS meaning), the S1SP shall create a SMETS1 Response indicating failure, since the DCC do not support such Instructions.

Affected device and firmware combinations

Manufacturer
Itron
Device Type
GSME
Model
RF1 Sv ZB
Firmware
012-00.292/10D6

18.25d · source row 208

Read Network Data

18.25d · Where the target SMETS1 ESME does not support the Average RMS Voltage Profile Data Log (with its SMETS1 meaning) to have a period that is the same as the AverageRMSVoltageMeasurementPeriod (with its DUIS meaning) set for calculation of Average RMS Voltage (with its SMETS1 meaning) and the AverageRMSVoltageMeasurementPeriod has not been set to be the same as the Average RMS Voltage Profile Data Log period, the values returned in the Average RMS Voltage Profile Data Log shall be averages for the AverageRMSVoltageMeasurementPeriod calculated at the time of each log entry.

Affected device and firmware combinations

Manufacturer
Honeywell
Device Type
ESME
Model
AS300P
Firmware
ASP 04.04.01-55497
Manufacturer
Honeywell
Device Type
ESME
Model
AS300P
Firmware
ASP 04.04.01-60250
Manufacturer
Itron
Device Type
ESME
Model
EM425-UK
Firmware
03.00.03.46/53.17
Manufacturer
Secure Meters
Device Type
ESME
Model
Liberty 100 (with aux)
Firmware
P4X9G01

18.25e · source row 209

Read Network Data

18.25e · Where the target SMETS1 ESME only supports the capture of voltages in the Average RMS Voltage Profile Data Log (with its SMETS1 meaning) with the same Average RMS Voltage Measurement Period (with its SMETS1 meaning), then any existing values, accessible via the AvgRMSVoltageProfileDataLog (with its MMC meaning), will be erased whenever Average RMS Voltage Measurement Period (with its SMETS1 meaning) is changed from its previous value.

Affected device and firmware combinations

Manufacturer
Secure Meters
Device Type
ESME
Model
Liberty 100 (with aux)
Firmware
P4X9G01