Service Reference Variant

6.2.1 · Read Device Configuration (Voltage)

Service details

Identifiers, rules, and applicability

Service reference
6.2
Service Reference Variant
6.2.1
DUIS section
3.8.46
Command variants
1, 2, 3
DUIS possible responses
AcknowledgementService Response from Device - GBCSPayloadResponse to a Command for Local Delivery Request - LocalCommand FormatCountersigned SMETS1 Response
Critical
No
Sensitive response
No
Protection against replay
No
On demand
Yes
Future dated
No
DSP scheduled
No
DCC only
No
SMETS1 applicability
Yes
SAPC requirement
Optional
DUIS applicability
3.0, 3.1, 4.0, 5.0, 5.1, 5.2, 5.3

Cross-specification evidence

SMETS/CHTS to GBCS Mapping

This section shows the SMETS and CHTS attributes that can be read or written by the identified GBCS Use Case. Command requirements are shown separately from the mapped attributes.

ECS26b10 attributes0x003CESME
SpecificationItemReferenceDescription
SMETSAverage RMS Over Voltage Threshold5.7.4.4The average RMS voltage above which an over voltage condition is reported. The threshold shall be configurable within the specified operating range of ESME.
SMETSAverage RMS Under Voltage Threshold5.7.4.5The average RMS voltage below which an under voltage condition is reported. The threshold shall be configurable within the specified operating range of ESME.
SMETSRMS Extreme Over Voltage Measurement Period5.7.4.34The duration in seconds used to measure an extreme over voltage condition.
SMETSRMS Extreme Over Voltage Threshold5.7.4.35The RMS voltage above which an extreme over voltage condition is reported. The threshold shall be configurable within the specified operating range of ESME.
SMETSRMS Extreme Under Voltage Measurement Period5.7.4.36The duration in seconds used to measure an extreme under voltage condition.
SMETSRMS Extreme Under Voltage Threshold5.7.4.37The RMS voltage below which an extreme under voltage condition is reported. The threshold shall be configurable within the specified operating range of ESME.
SMETSRMS Voltage Sag Measurement Period5.7.4.38The duration in seconds used to measure a voltage sag condition.
SMETSRMS Voltage Swell Measurement Period5.7.4.39The duration in seconds used to measure a voltage swell condition.
SMETSRMS Voltage Sag Threshold5.7.4.40The RMS voltage below which a sag condition is reported. The threshold shall be configurable within the specified operating range of ESME.
SMETSRMS Voltage Swell Threshold5.7.4.41The RMS voltage above which a swell condition is reported. The threshold shall be configurable within the specified operating range of ESME.
ECS26k12 attributes0x00C6ESME
SpecificationItemReferenceDescription
SMETSAverage RMS Over Voltage Threshold5.7.4.4The average RMS voltage above which an over voltage condition is reported. The threshold shall be configurable within the specified operating range of ESME.
SMETSAverage RMS Under Voltage Threshold5.7.4.5The average RMS voltage below which an under voltage condition is reported. The threshold shall be configurable within the specified operating range of ESME.
SMETSRMS Extreme Over Voltage Measurement Period5.7.4.34The duration in seconds used to measure an extreme over voltage condition.
SMETSRMS Extreme Over Voltage Threshold5.7.4.35The RMS voltage above which an extreme over voltage condition is reported. The threshold shall be configurable within the specified operating range of ESME.
SMETSRMS Extreme Under Voltage Measurement Period5.7.4.36The duration in seconds used to measure an extreme under voltage condition.
SMETSRMS Extreme Under Voltage Threshold5.7.4.37The RMS voltage below which an extreme under voltage condition is reported. The threshold shall be configurable within the specified operating range of ESME.
SMETSRMS Voltage Sag Measurement Period5.7.4.38The duration in seconds used to measure a voltage sag condition.
SMETSRMS Voltage Swell Measurement Period5.7.4.39The duration in seconds used to measure a voltage swell condition.
SMETSRMS Voltage Sag Threshold5.7.4.40The RMS voltage below which a sag condition is reported. The threshold shall be configurable within the specified operating range of ESME.
SMETSRMS Voltage Swell Threshold5.7.4.41The RMS voltage above which a swell condition is reported. The threshold shall be configurable within the specified operating range of ESME.
SMETSPhase [n] Average RMS Over Voltage Threshold5.19.1.1The average RMS voltage for phase [n] above which an over voltage condition is reported. The threshold shall be configurable within the specified operating range of ESME.
SMETSPhase [n] Average RMS Under Voltage Threshold5.19.1.2The average RMS voltage for phase [n] below which an under voltage condition is reported. The threshold shall be configurable within the specified operating range of ESME.

Specific Errors

Response codes and descriptions

No specific validation is defined for this SRV.

GBCS Use Case

Use cases, device coverage, and applicability

Use Case / Message Code
ECS26b0x003C
DUIS Applicability
v3.0 – v5.3
GBCS Applicability
v1.0 – v4.3
GBCS Criticality
Non-Critical
Sensitive Response
No
Future Dated
No
GBT
No
SMETS1 Applicable
Yes
Eligible Roles
EISSNAENOESME
Use Case / Message Code
ECS26k0x00C6
DUIS Applicability
v3.0 – v5.3
GBCS Applicability
v1.0 – v4.3
GBCS Criticality
Non-Critical
Sensitive Response
No
Future Dated
No
GBT
No
SMETS1 Applicable
No
Eligible Roles
EISSNAENOESME

Message Patterns & Examples

Pattern explorer

Open Message Patterns →

SMETS1 Supporting Requirements

Device-model variations and equivalent steps

Review the Section 18 requirements and their applicability across the documented manufacturer, Device Type, model, and firmware profiles.

Open S1SR Requirements →