Service Reference Variant

6.5 · Update Device Configuration (Voltage)

Service details

Identifiers, rules, and applicability

Service reference
6.5
Service Reference Variant
6.5
DUIS section
3.8.57
Command variants
1, 2, 3
DUIS possible responses
AcknowledgementService Response from Device - GBCSPayloadResponse to a Command for Local Delivery Request - LocalCommand FormatCountersigned SMETS1 Response
Critical
No
Sensitive response
No
Protection against replay
Yes
On demand
Yes
Future dated
DSP
DSP scheduled
No
DCC only
No
SMETS1 applicability
Yes
SAPC requirement
Optional
DUIS applicability
3.0, 3.1, 4.0, 5.0, 5.1, 5.2, 5.3

Cross-specification evidence

SMETS/CHTS to GBCS Mapping

This section shows the SMETS and CHTS attributes that can be read or written by the identified GBCS Use Case. Command requirements are shown separately from the mapped attributes.

ECS29a2 commands12 attributes0x0045ESME

Commands mapped to ECS29a

  • SMETSReset Average RMS Over Voltage Counter5.6.3.22ESME
  • SMETSReset Average RMS Under Voltage Counter5.6.3.23ESME
SpecificationItemReferenceDescription
SMETSAverage RMS Over Voltage Threshold5.7.4.4The average RMS voltage above which an over voltage condition is reported. The threshold shall be configurable within the specified operating range of ESME.
SMETSAverage RMS Under Voltage Threshold5.7.4.5The average RMS voltage below which an under voltage condition is reported. The threshold shall be configurable within the specified operating range of ESME.
SMETSAverage RMS Voltage Measurement Period5.7.4.6The length of time in seconds over which the RMS voltage is averaged.
SMETSRMS Extreme Over Voltage Measurement Period5.7.4.34The duration in seconds used to measure an extreme over voltage condition.
SMETSRMS Extreme Over Voltage Threshold5.7.4.35The RMS voltage above which an extreme over voltage condition is reported. The threshold shall be configurable within the specified operating range of ESME.
SMETSRMS Extreme Under Voltage Measurement Period5.7.4.36The duration in seconds used to measure an extreme under voltage condition.
SMETSRMS Extreme Under Voltage Threshold5.7.4.37The RMS voltage below which an extreme under voltage condition is reported. The threshold shall be configurable within the specified operating range of ESME.
SMETSRMS Voltage Sag Measurement Period5.7.4.38The duration in seconds used to measure a voltage sag condition.
SMETSRMS Voltage Swell Measurement Period5.7.4.39The duration in seconds used to measure a voltage swell condition.
SMETSRMS Voltage Sag Threshold5.7.4.40The RMS voltage below which a sag condition is reported. The threshold shall be configurable within the specified operating range of ESME.
SMETSRMS Voltage Swell Threshold5.7.4.41The RMS voltage above which a swell condition is reported. The threshold shall be configurable within the specified operating range of ESME.
SMETSPhase [n] Average RMS Voltage Measurement Period5.19.1.3The length of time in seconds over which the RMS voltage is averaged for phase [n].
ECS29b4 commands14 attributes0x00AEESME

Commands mapped to ECS29b

  • SMETSReset Average RMS Over Voltage Counter5.6.3.22ESME
  • SMETSReset Average RMS Under Voltage Counter5.6.3.23ESME
  • SMETSReset Phase [n] Average RMS Over Voltage Counter5.18.1.1ESME
  • SMETSReset Phase [n] Average RMS Under Voltage Counter5.18.1.2ESME
SpecificationItemReferenceDescription
SMETSAverage RMS Over Voltage Threshold5.7.4.4The average RMS voltage above which an over voltage condition is reported. The threshold shall be configurable within the specified operating range of ESME.
SMETSAverage RMS Under Voltage Threshold5.7.4.5The average RMS voltage below which an under voltage condition is reported. The threshold shall be configurable within the specified operating range of ESME.
SMETSAverage RMS Voltage Measurement Period5.7.4.6The length of time in seconds over which the RMS voltage is averaged.
SMETSRMS Extreme Over Voltage Measurement Period5.7.4.34The duration in seconds used to measure an extreme over voltage condition.
SMETSRMS Extreme Over Voltage Threshold5.7.4.35The RMS voltage above which an extreme over voltage condition is reported. The threshold shall be configurable within the specified operating range of ESME.
SMETSRMS Extreme Under Voltage Measurement Period5.7.4.36The duration in seconds used to measure an extreme under voltage condition.
SMETSRMS Extreme Under Voltage Threshold5.7.4.37The RMS voltage below which an extreme under voltage condition is reported. The threshold shall be configurable within the specified operating range of ESME.
SMETSRMS Voltage Sag Measurement Period5.7.4.38The duration in seconds used to measure a voltage sag condition.
SMETSRMS Voltage Swell Measurement Period5.7.4.39The duration in seconds used to measure a voltage swell condition.
SMETSRMS Voltage Sag Threshold5.7.4.40The RMS voltage below which a sag condition is reported. The threshold shall be configurable within the specified operating range of ESME.
SMETSRMS Voltage Swell Threshold5.7.4.41The RMS voltage above which a swell condition is reported. The threshold shall be configurable within the specified operating range of ESME.
SMETSPhase [n] Average RMS Over Voltage Threshold5.19.1.1The average RMS voltage for phase [n] above which an over voltage condition is reported. The threshold shall be configurable within the specified operating range of ESME.
SMETSPhase [n] Average RMS Under Voltage Threshold5.19.1.2The average RMS voltage for phase [n] below which an under voltage condition is reported. The threshold shall be configurable within the specified operating range of ESME.
SMETSPhase [n] Average RMS Voltage Measurement Period5.19.1.3The length of time in seconds over which the RMS voltage is averaged for phase [n].
ECS29c14 attributes0x00D1ESME
SpecificationItemReferenceDescription
SMETSAverage RMS Over Voltage Threshold5.7.4.4The average RMS voltage above which an over voltage condition is reported. The threshold shall be configurable within the specified operating range of ESME.
SMETSAverage RMS Under Voltage Threshold5.7.4.5The average RMS voltage below which an under voltage condition is reported. The threshold shall be configurable within the specified operating range of ESME.
SMETSAverage RMS Voltage Measurement Period5.7.4.6The length of time in seconds over which the RMS voltage is averaged.
SMETSRMS Extreme Over Voltage Measurement Period5.7.4.34The duration in seconds used to measure an extreme over voltage condition.
SMETSRMS Extreme Over Voltage Threshold5.7.4.35The RMS voltage above which an extreme over voltage condition is reported. The threshold shall be configurable within the specified operating range of ESME.
SMETSRMS Extreme Under Voltage Measurement Period5.7.4.36The duration in seconds used to measure an extreme under voltage condition.
SMETSRMS Extreme Under Voltage Threshold5.7.4.37The RMS voltage below which an extreme under voltage condition is reported. The threshold shall be configurable within the specified operating range of ESME.
SMETSRMS Voltage Sag Measurement Period5.7.4.38The duration in seconds used to measure a voltage sag condition.
SMETSRMS Voltage Swell Measurement Period5.7.4.39The duration in seconds used to measure a voltage swell condition.
SMETSRMS Voltage Sag Threshold5.7.4.40The RMS voltage below which a sag condition is reported. The threshold shall be configurable within the specified operating range of ESME.
SMETSRMS Voltage Swell Threshold5.7.4.41The RMS voltage above which a swell condition is reported. The threshold shall be configurable within the specified operating range of ESME.
SMETSPhase [n] Average RMS Over Voltage Threshold5.19.1.1The average RMS voltage for phase [n] above which an over voltage condition is reported. The threshold shall be configurable within the specified operating range of ESME.
SMETSPhase [n] Average RMS Under Voltage Threshold5.19.1.2The average RMS voltage for phase [n] below which an under voltage condition is reported. The threshold shall be configurable within the specified operating range of ESME.
SMETSPhase [n] Average RMS Voltage Measurement Period5.19.1.3The length of time in seconds over which the RMS voltage is averaged for phase [n].
ECS29d14 attributes0x00D2ESME
SpecificationItemReferenceDescription
SMETSAverage RMS Over Voltage Threshold5.7.4.4The average RMS voltage above which an over voltage condition is reported. The threshold shall be configurable within the specified operating range of ESME.
SMETSAverage RMS Under Voltage Threshold5.7.4.5The average RMS voltage below which an under voltage condition is reported. The threshold shall be configurable within the specified operating range of ESME.
SMETSAverage RMS Voltage Measurement Period5.7.4.6The length of time in seconds over which the RMS voltage is averaged.
SMETSRMS Extreme Over Voltage Measurement Period5.7.4.34The duration in seconds used to measure an extreme over voltage condition.
SMETSRMS Extreme Over Voltage Threshold5.7.4.35The RMS voltage above which an extreme over voltage condition is reported. The threshold shall be configurable within the specified operating range of ESME.
SMETSRMS Extreme Under Voltage Measurement Period5.7.4.36The duration in seconds used to measure an extreme under voltage condition.
SMETSRMS Extreme Under Voltage Threshold5.7.4.37The RMS voltage below which an extreme under voltage condition is reported. The threshold shall be configurable within the specified operating range of ESME.
SMETSRMS Voltage Sag Measurement Period5.7.4.38The duration in seconds used to measure a voltage sag condition.
SMETSRMS Voltage Swell Measurement Period5.7.4.39The duration in seconds used to measure a voltage swell condition.
SMETSRMS Voltage Sag Threshold5.7.4.40The RMS voltage below which a sag condition is reported. The threshold shall be configurable within the specified operating range of ESME.
SMETSRMS Voltage Swell Threshold5.7.4.41The RMS voltage above which a swell condition is reported. The threshold shall be configurable within the specified operating range of ESME.
SMETSPhase [n] Average RMS Over Voltage Threshold5.19.1.1The average RMS voltage for phase [n] above which an over voltage condition is reported. The threshold shall be configurable within the specified operating range of ESME.
SMETSPhase [n] Average RMS Under Voltage Threshold5.19.1.2The average RMS voltage for phase [n] below which an under voltage condition is reported. The threshold shall be configurable within the specified operating range of ESME.
SMETSPhase [n] Average RMS Voltage Measurement Period5.19.1.3The length of time in seconds over which the RMS voltage is averaged for phase [n].

Specific Errors

Response codes and descriptions

Response CodeResponse Code Description
E060501
The Voltage Settings aren’t applicable to the Electricity Smart Meter variant as defined in the Smart Metering Inventory
E060502
The GBCS version that pertains to the Device Model recorded in the SMI for this Device, does not support the chosen features of this Service Request

Source: DUIS 3.8.57.3

GBCS Use Case

Use cases, device coverage, and applicability

Use Case / Message Code
ECS29a0x0045
DUIS Applicability
v3.0 – v5.3
GBCS Applicability
v1.0 – v4.3
GBCS Criticality
Non-Critical
Sensitive Response
No
Future Dated
DSP
GBT
No
SMETS1 Applicable
Yes
Eligible Roles
ENOESME
Use Case / Message Code
ECS29b0x00AE
DUIS Applicability
v3.0 – v5.3
GBCS Applicability
v1.0 – v4.3
GBCS Criticality
Non-Critical
Sensitive Response
No
Future Dated
DSP
GBT
No
SMETS1 Applicable
No
Eligible Roles
ENOESME
Use Case / Message Code
ECS29c0x00D1
DUIS Applicability
v3.0 – v5.3
GBCS Applicability
v2.0 – v4.3
GBCS Criticality
Non-Critical
Sensitive Response
No
Future Dated
DSP
GBT
No
SMETS1 Applicable
Yes
Eligible Roles
ENOESME
Use Case / Message Code
ECS29d0x00D2
DUIS Applicability
v3.0 – v5.3
GBCS Applicability
v2.0 – v4.3
GBCS Criticality
Non-Critical
Sensitive Response
No
Future Dated
DSP
GBT
No
SMETS1 Applicable
No
Eligible Roles
ENOESME

DUIS Service Definition

Data items and DCC processing

Request data items

Table 165: UpdateDeviceConfigurationVoltage (sr:UpdateDeviceConfigurationVoltage) data items
Data ItemDescription / Valid SetTypeMandatoryDefaultUnits
ExecutionDateTimeA User shall only add this Data Item to the Service Request where they require the Service Request to be executed at a future date and time. The UTC date and time the User requires the command to be executed on the Device Date-time in the future that is either <= current date + 30 days or the date = ‘3000-12-31T00:00:00Z’xs:dateTimeNoNoneUTC Date-Time
RMSVoltageSettingsThe non-average RMS Voltage settings applicable to a Single Phase (Single or Twin Element) Electricity Smart Meter or to a Polyphase Electricity Smart Meter phase.sr:RMSVoltageSettingsYesNoneN/A
SinglePhaseVoltageSettingsThe average voltage settings applicable to a Single Phase (Single or Twin Element) Electricity Smart Meter.sr:AverageRMSVoltageSettingsSingle / Twin Element Electricity Smart Meter: Yes Polyphase Electricity Smart Meter: N/ANoneN/A
PolyPhaseVoltageSettingsThe average voltage settings applicable to a PolyPhase Electricity Smart Meter.sr:PolyPhaseVoltageSettings (minOccurs = “3”, maxOccurs = “3”)Single / Twin Element Electricity Smart Meter: N/A Polyphase Electricity Smart Meter: YesNoneN/A
RMSVoltageCountersNotResetFlag to indicate that the RMS Voltage Counters are not to be reset. RMSVoltageCountersNotReset is only supported on Devices with a Device Model recorded in the Smart Metering Inventory that pertains to GBCS version 2.0 according to the entry for that Device Model in the Central Products List. Its inclusion is used by the DCC Systems to map the Service Request to GBCS Use Cases ECS29c (single phase) / ECS29d (poly phase) and its absence to ECS29a (single phase) / ECS29b (poly phase)sr:NoTypeNoNoneN/A
Table 166: PolyPhaseVoltageSettings (sr:PolyPhaseVoltageSettings) data items
Data ItemDescription / Valid SetTypeMandatoryDefaultUnits
PhaseThe number (n: 1, 2, 3) of the phase to which the Phase voltage Settings applyRestriction of xs:positiveInteger minInclusive = 1. maxInclusive =3)YesNoneN/A
PhaseVoltageSettingsThe average voltage settings applicable to each of the phases.sr:AverageRMSVoltageSettingsYesNoneN/A
Table 167: AverageRMSVoltageSettings (sr:AverageRMSVoltageSettings) data items
Data ItemDescription / Valid SetTypeMandatoryDefaultUnits
AverageRMSOverVoltageThresholdThe average RMS voltage above which an over voltage condition is reportedxs:unsignedIntYesNone10th Volt
AverageRMSUnderVoltageThresholdThe average RMS voltage below which an over voltage condition is reportedxs:unsignedIntYesNone10th Volt
AverageRMSVoltageMeasurementPeriodThe length of time in seconds over which the RMS voltage is averagedxs:unsignedIntYesNoneSeconds
Table 168: RMSVoltageSettings (sr:RMSVoltageSettings) data items
Data ItemDescription / Valid SetTypeMandatoryDefaultUnits
RMSExtremeOverVoltageMeasurementPeriodThe duration in seconds used to measure an extreme over voltage conditionxs:unsignedIntYesNoneSeconds
RMSExtremeOverVoltageThresholdThe RMS voltage above which an extreme over voltage condition is reported.xs: unsignedIntYesNone10th Volt
RMSExtremeUnderVoltageMeasurementPeriodThe duration in seconds used to measure an extreme under voltage conditionxs:unsignedIntYesNoneSeconds
RMSExtremeUnderVoltageThresholdThe RMS voltage below which an extreme over voltage condition is reported. The threshold shall be configurable within the specified operating range of Electricity Smart Meterxs:unsignedIntYesNone10th Volt
RMSVoltageSagMeasurementPeriodThe duration in seconds used to measure a voltage sag conditionxs:unsignedIntYesNoneSeconds
RMSVoltageSwellMeasurementPeriodThe duration in seconds used to measure a voltage swell conditionxs:unsignedIntYesNoneSeconds
RMSVoltageSagThresholdThe RMS voltage below which a sag condition is reported. The threshold shall be configurable within the specified operating range of Electricity Smart Meterxs:unsignedIntYesNone10th Volt
RMSVoltageSwellThresholdThe RMS voltage above which a swell condition is reported. The threshold shall be configurable within the specified operating range of Electricity Smart Meterxs:unsignedIntYesNone10th Volt

DUGIDS service matrix

DUGIDS DS.0226 Table 36 footnote extract

FootnoteExtractColumnCell ValueSource
9No for SMETS1 DevicesProtection Against ReplayYesDS.0226 Table 36 Service Request Matrix

Message Patterns & Examples

Pattern explorer

Open Message Patterns →

SMETS1 Supporting Requirements

Device-model variations and equivalent steps

Review the Section 18 requirements and their applicability across the documented manufacturer, Device Type, model, and firmware profiles.

Open S1SR Requirements →