Service Reference Variant

6.7 · Update Device Configuration (Gas Flow)

Service details

Identifiers, rules, and applicability

Service reference
6.7
Service Reference Variant
6.7
DUIS section
3.8.59
Command variants
4, 5, 6, 7
DUIS possible responses
AcknowledgementResponse to Transform Request - PreCommand FormatService Response from Device - GBCSPayloadResponse to a Command for Local Delivery Request - LocalCommand FormatCountersigned SMETS1 Response
Critical
Yes
Sensitive response
No
Protection against replay
Yes
On demand
Yes
Future dated
No
DSP scheduled
No
DCC only
No
SMETS1 applicability
Yes
SAPC requirement
Not stated
DUIS applicability
3.0, 3.1, 4.0, 5.0, 5.1, 5.2, 5.3

Cross-specification evidence

SMETS/CHTS to GBCS Mapping

This section shows the SMETS and CHTS attributes that can be read or written by the identified GBCS Use Case. Command requirements are shown separately from the mapped attributes.

GCS24a3 attributes0x00FCGSME
SpecificationItemReferenceDescription
SMETSSupply Depletion State4.6.4.25A setting to control the state of the Supply in the case of loss of power to GSME, being Locked or unchanged.
SMETSSupply Tamper State4.6.4.26A setting to control the state of the Supply in the case of Unauthorised Physical Access being detected, being Locked or unchanged.
SMETSUncontrolled Gas Flow Rate4.6.4.33The flow rate in units of volume per unit time used in the detection of uncontrolled flow of gas on Enablement of Supply.

Specific Errors

Response codes and descriptions

Response CodeResponse Code Description
E060701
The GBCS version that pertains to the Device Model recorded in the SMI for this Device doesn’t support the requested value format for Uncontrolled Gas Flow Rate .

Source: DUIS 3.8.59.3

SMETS1-specific validation

Additional SMETS1 conditions are shown separately from the SRV-specific DUIS table.

SMETS1 supplementary validation
E060701

If the target Device is a SMETS1 GSME according to the Smart Metering Inventory, the XML element named UncontrolledGasFlowRateDecimal must not be included in the Service Request.For clarity, only the XML element named UncontrolledGasFlowRate may be used with SMETS1 devices

Applies to: Amended condition for SMETS1 Devices

Source: DUIS 1.4.6 Table 2

GBCS Use Case

Use cases, device coverage, and applicability

Use Case / Message Code
GCS240x007D
DUIS Applicability
v3.0 – v5.3
GBCS Applicability
v2.0 – v3.1
GBCS Criticality
Critical
Sensitive Response
No
Future Dated
No
GBT
No
SMETS1 Applicable
Yes
Eligible Roles
GISGSME
Use Case / Message Code
GCS24a0x00FC
DUIS Applicability
v3.1 – v5.3
GBCS Applicability
v3.2 – v4.3
GBCS Criticality
Critical
Sensitive Response
No
Future Dated
No
GBT
No
SMETS1 Applicable
No
Eligible Roles
GISGSME

DUIS Service Definition

Data items and DCC processing

Request data items

Table 170: UpdateDeviceConfigurationGasFlow (sr:UpdateDeviceConfigurationGasFlow) data items
Data ItemDescription / Valid SetTypeMandatoryDefaultUnits
UncontrolledGasFlowRateThe flow rate in units of volume per unit time used in the detection of uncontrolled flow of gas on Enablement of Supply UncontrolledGasFlowRate is only supported on Devices with a Device Model recorded in the Smart Metering Inventory that pertains to GBCS version 1.0 or 2.0 according to the entry for that Device Model in the Central Products Listxs:unsignedShortWhere the GBCS Version is Version 1.0 or 2.0: Yes Otherwise: N/ANonem3/hour
UncontrolledGasFlowRateDecimalThe flow rate in units of volume per unit time used in the detection of uncontrolled flow of gas on Enablement of Supply UncontrolledGasFlowRateDecimal is only supported on Devices with a Device Model recorded in the Smart Metering Inventory that pertains to GBCS version 3.2 according to the entry for that Device Model in the Central Products ListRestriction of xs:decimal (minInclusive = 0, maxInclusive = 6.5535, fractionDigits=4)Where the GBCS Version is Version 3.2: Yes Otherwise: N/ANonem3/hour
SupplyDepletionStateA setting to control the state of the Supply in the case of loss of power to the Gas Smart Meter Valid set: Unchanged LockedRestriction of xs:string (Enumeration)YesNoneN/A
SupplyTamperStateA setting to control the state of the Supply in the case of a Tamper Event being detected Valid set: Unchanged LockedRestriction of xs:string (Enumeration)YesNoneN/A
StabilisationPeriodValue indicating the time given to allow the flow to stabilize. It is defined in units of tenths of a secondRestriction of xs:positiveInteger (minInclusive = 1, maxInclusive = 255)YesNone10th second
MeasurementPeriodValue indicating the period over which the flow is measured and compared against the Uncontrolled Flow Threshold value. It is defined in units of 1 secondRestriction of xs:positiveInteger (minInclusive = 1, maxInclusive = 65535)YesNoneSeconds

Message Patterns & Examples

Pattern explorer

Open Message Patterns →

SMETS1 Supporting Requirements

Device-model variations and equivalent steps

Review the Section 18 requirements and their applicability across the documented manufacturer, Device Type, model, and firmware profiles.

Open S1SR Requirements →