SMETS requirement clause

4.6.4.33 — Uncontrolled Gas Flow Rate

6 technical records havebeen identified at this reference: 6 Section 20 items and 0 explicit clause references. The links below describe documented interfaces and observable effects; they do not assert compliance with the source requirement.

GSMESRV touchpoint
6

Atomic items

Section 20 objects, attributes or methods at this source reference.

6

Documented touchpoints

Typed relationships supported by source mapping rows.

2

Linked SRVs

Unique retained services reached through exact control rows.

0

Linked alerts

Explicit requirement-to-alert references.

SMETS4.6.4.33 · item UncontrolledGasFlowRate.methodInput: threshold

UncontrolledGasFlowRate - threshold

SRV touchpoint

The value to set

Object
UncontrolledGasFlowRate
Attribute / method
methodInput: threshold
Interface disposition
E
Category
Method Input
Section 20 meaning
The value to set

Documented touchpoints

Evidence:source paragraph 708, 709Section 20 row 1402

SMETS4.6.4.33 · item UncontrolledGasFlowRate.value

UncontrolledGasFlowRate - value

SRV touchpoint

The threshold value

Object
UncontrolledGasFlowRate
Attribute / method
value
Interface disposition
E
Category
Operational data
Section 20 meaning
The threshold value

Documented touchpoints

Evidence:source paragraph 708, 709Section 20 row 1754

SMETS4.6.4.33 · item UncontrolledGasFlowRate.methodInput: stabilisationPeriod

UncontrolledGasFlowRate - stabilisationPeriod

SRV touchpoint

Time given for flow to stabilise, in tenths of a second

Object
UncontrolledGasFlowRate
Attribute / method
methodInput: stabilisationPeriod
Interface disposition
E
Category
Method Input
Section 20 meaning
Time given for flow to stabilise, in tenths of a second

Documented touchpoints

Evidence:source paragraph 708, 709Section 20 row 1867

SMETS4.6.4.33 · item UncontrolledGasFlowRate.methodInput: measurementPeriod

UncontrolledGasFlowRate - measurementPeriod

SRV touchpoint

Period over which the flow is measured, in seconds

Object
UncontrolledGasFlowRate
Attribute / method
methodInput: measurementPeriod
Interface disposition
E
Category
Method Input
Section 20 meaning
Period over which the flow is measured, in seconds

Documented touchpoints

Evidence:source paragraph 708, 709Section 20 row 1868

SMETS4.6.4.33 · item UncontrolledGasFlowRate.stabilisationPeriod

UncontrolledGasFlowRate - stabilisationPeriod

SRV touchpoint

Time given for flow to stabilise, in tenths of a second

Object
UncontrolledGasFlowRate
Attribute / method
stabilisationPeriod
Interface disposition
E
Category
Configuration data
Section 20 meaning
Time given for flow to stabilise, in tenths of a second

Documented touchpoints

Evidence:source paragraph 708, 709Section 20 row 1869

SMETS4.6.4.33 · item UncontrolledGasFlowRate.measurementPeriod

UncontrolledGasFlowRate - measurementPeriod

SRV touchpoint

Period over which the flow is measured, in seconds

Object
UncontrolledGasFlowRate
Attribute / method
measurementPeriod
Interface disposition
E
Category
Configuration data
Section 20 meaning
Period over which the flow is measured, in seconds

Documented touchpoints

Evidence:source paragraph 708, 709Section 20 row 1870

How to read this page

Evidence is kept at record level

A source clause can contain several separately mapped Section 20 items and an explicit alert reference. One item may be read by an SRV, another updated by a different service, and another have only an Alert or local-HAN path. Accordingly, the clause summary does not collapse those distinctions into a single covered or uncovered result.