SMETS requirement clause

5.13.2.1 — Active Power Import [INFO]

7 technical records havebeen identified at this reference: 7 Section 20 items and 0 explicit clause references. The links below describe documented interfaces and observable effects; they do not assert compliance with the source requirement.

ESMENo Section 20 bridgeSRV touchpoint
7

Atomic items

Section 20 objects, attributes or methods at this source reference.

4

Documented touchpoints

Typed relationships supported by source mapping rows.

1

Linked SRVs

Unique retained services reached through exact control rows.

0

Linked alerts

Explicit requirement-to-alert references.

SMETS5.13.2.1 · item ActivePowerImport.scale

ActivePowerImport - scale

No Section 20 bridge

0 (power of 10 to apply when interpreting the value attribute)

Object
ActivePowerImport
Attribute / method
scale
Interface disposition
E
Category
Constant data
Section 20 meaning
0 (power of 10 to apply when interpreting the value attribute)

No GBCS or SRV bridge is recorded for this item in the current Section 20 mapping. This is an evidence status, not a statement of non-compliance.

Evidence:source paragraph 1918, 1919Section 20 row 1557

SMETS5.13.2.1 · item ActivePowerImport.unit

ActivePowerImport - unit

No Section 20 bridge

W

Object
ActivePowerImport
Attribute / method
unit
Interface disposition
E
Category
Constant data
Section 20 meaning
W

No GBCS or SRV bridge is recorded for this item in the current Section 20 mapping. This is an evidence status, not a statement of non-compliance.

Evidence:source paragraph 1918, 1919Section 20 row 1709

SMETS5.13.2.1 · item ActivePowerImport.value

ActivePowerImport - value

No Section 20 bridge

On a Twin Element Meter, this is the sum of the PrimaryActivePowerImport.value and SecondaryActivePowerImport.value. On other ESME, it is equal to the PrimaryActivePowerImport.value

Object
ActivePowerImport
Attribute / method
value
Interface disposition
E
Category
Operational data
Section 20 meaning
On a Twin Element Meter, this is the sum of the PrimaryActivePowerImport.value and SecondaryActivePowerImport.value. On other ESME, it is equal to the PrimaryActivePowerImport.value

No GBCS or SRV bridge is recorded for this item in the current Section 20 mapping. This is an evidence status, not a statement of non-compliance.

Evidence:source paragraph 1918, 1919Section 20 row 1739

SMETS5.13.2.1 · item PowerImportCollection.ActivePowerImport.value

PowerImportCollection - ActivePowerImport value

SRV touchpoint

This is the total active Power from all elements on the meter

Object
PowerImportCollection
Attribute / method
ActivePowerImport.value
Interface disposition
E
Category
Operational data
Section 20 meaning
This is the total active Power from all elements on the meter

Documented touchpoints

Evidence:source paragraph 1918, 1919Section 20 row 25

SMETS5.13.2.1 · item PowerImportCollection.PrimaryActivePowerImport.value

PowerImportCollection - PrimaryActivePowerImport value

SRV touchpoint

This is the total active Power from the first element on the meter

Object
PowerImportCollection
Attribute / method
PrimaryActivePowerImport.value
Interface disposition
E
Category
Operational data
Section 20 meaning
This is the total active Power from the first element on the meter

Documented touchpoints

Evidence:source paragraph 1918, 1919Section 20 row 26

SMETS5.13.2.1 · item PowerImportCollection.ActivePowerImport.unit

PowerImportCollection - ActivePowerImport unit

SRV touchpoint

W

Object
PowerImportCollection
Attribute / method
ActivePowerImport.unit
Interface disposition
E
Category
Operational data
Section 20 meaning
W

Documented touchpoints

Evidence:source paragraph 1918, 1919Section 20 row 40

SMETS5.13.2.1 · item PowerImportCollection.ActivePowerImport.scaler

PowerImportCollection - ActivePowerImport scaler

SRV touchpoint

0 (power of 10 to apply when interpreting the value attribute)

Object
PowerImportCollection
Attribute / method
ActivePowerImport.scaler
Interface disposition
E
Category
Operational data
Section 20 meaning
0 (power of 10 to apply when interpreting the value attribute)

Documented touchpoints

Evidence:source paragraph 1918, 1919Section 20 row 43

How to read this page

Evidence is kept at record level

A source clause can contain several separately mapped Section 20 items and an explicit alert reference. One item may be read by an SRV, another updated by a different service, and another have only an Alert or local-HAN path. Accordingly, the clause summary does not collapse those distinctions into a single covered or uncovered result.