Business Processes / 1.5.1

Install And Commission (ESME Credit)

25 primary steps · 3 associated steps

StepSRVDescriptionComment
18.11Update HAN Device LogChange in InstallCode field attribute – DUIS3.0 onwards
1.1Wait For Device Alert 0x8F69/N24Energy supplier will not receive alert 0x8F69 if ACB certificates are in Device trust anchor slot.
28.9Read Device LogOptional. In the case of N25, this will help verify that SR8.11 was successful.
38.14.1Communications Hub Status Update- Install SuccessIf this is not sent, the CSP will not be able to establish the address of the CH efficiently this will cause challenges in the incident investigation process. This SR should only be sent once. If all the parameters necessary to send SR 8.14.1 are not available at the time of this I and C process, then this SR must be sent later as soon as all the parameters are available and within the 5-day SLA as set in SEC Appendix I. The I and C process can continue and not be blocked due to not being able to send the SR at this step. Please note that this SR is mandatory and must be sent within the 5-day SLA.
46.24.1Retrieve Device Security Credentials (KRP)This is only optional if the installing supplier does not know what certificates are inside the supplier trust anchor cell.
56.23Update Security Credential (CoS)This SR will only be necessary if ACB certificates are not pre-populated in the Trust Anchor Cell during manufacture. This should only be used if the supplier certs in the Supplier Trust Anchor cell belong to another supplier.
66.15.1Update Security Credentials (KRP)This SR will be necessary if the supplier certs in the supplier trust anchor cell are those of the installing supplier.
76.21Request Handover Of DCC Controlled DeviceUpdate Supplier Certificates (ESME). Default process which should be used if the ACB certs are in the Trust anchor cell of the supplier.
88.1.1Commission Device
96.20.1Set Device Configuration (Import MPxN)
101.1.1Update Import Tariff (Primary Element)
111.6Update Payment Mode
126.8Update Device Configuration (Billing Calendar)
135.1Create Schedule
146.22Configure Alert Behaviour
154.4.2Retrieve Change of Mode/Tariff Triggered Billing Data Log
161.5Update Meter Balance
173.4Update Supplier Name
186.4.1Update Device Configuration (Load Limiting)
196.12Update Device Configuration (Instantaneous Power Threshold)
206.25Set Electricity Supply Tamper State
216.21Request Handover Of DCC Controlled DeviceENO Certificates
226.17Issue Security CredentialDigital Signature - ESME
22.1Retrieve Certificate From SMKI
236.15.2Update Security Credential (Device)Digital Signature - ESME
246.17Issue Security CredentialKey Agreement Key- ESME
24.1Retrieve Certificate From SMKI
256.15.2Update Security Credential (Device)Key Agreement Key-ESME