Business Processes / 1.6.2
Install And Commission – ESME Prepayment
27 primary steps · 4 associated steps
| Step | SRV | Description | Comment |
|---|---|---|---|
| 1 | 8.11 | Update HAN Device Log | Change in InstallCode field attribute – DUIS3.0 Onwards |
| 1.1 | — | Wait For Device Alert 0x8F69/N24 | Energy supplier will not receive alert 0x8F69 if ACB certificates are in Device Trust Anchor Slot |
| 2 | 8.9 | Read Device Log | Optional. In the case of N25, this will help verify that SR8.11 was successful. |
| 3 | 8.14.1 | Communications Hub Status Update- Install Success | — |
| 4 | 6.24.1 | Retrieve Device Security Credentials (KRP) | This is only optional if the installing supplier does not know what certificates are inside the supplier trust anchor cell. |
| 5 | 6.23 | Update Security Credential (CoS) | This SR will only be necessary if ACB certificates are not pre-populated in the Trust Anchor Cell during manufacture. This should only be used if the supplier certs in the Supplier Trust Anchor cell belong to another supplier. |
| 6 | 6.15.1 | Update Security Credentials (KRP) | This SR will be necessary if the supplier certs in the supplier trust anchor cell are those of the installing supplier. |
| 7 | 6.21 | Request Handover Of DCC Controlled Device | Update Supplier Certificates. Default process which should be used if the ACB certs are in the Trust anchor cell of the supplier. |
| 8 | 8.11 | Commission Device | — |
| 9 | 6.20.1 | Set Device Configuration (Import MPxN) | — |
| 10 | 1.1.1 | Update Import Tariff (Primary Element) | — |
| 11 | 2.1 | Update Prepay Configuration | — |
| 12 | 1.6 | Update Payment Mode | — |
| 13 | 6.8 | Update Device Configuration (Billing Calendar) | — |
| 14 | 5.1 | Create Schedule | — |
| 15 | 6.22 | Configure Alert Behaviour | — |
| 16 | 4.4.2 | Retrieve Change of Mode/Tariff | — |
| 16.1 | — | Triggered Billing Data Log | — |
| 17 | 2.3 | Billing Data Log | — |
| 18 | 1.5 | Update Meter Balance | — |
| 19 | 3.4 | Update Supplier Name | — |
| 20 | 6.4.1 | Update Device Configuration (Load Limiting) | — |
| 21 | 6.12 | Update Device Configuration (Instantaneous Power Threshold) | — |
| 22 | 6.25 | Set Electricity Supply Tamper State | — |
| 23 | 6.21 | Request Handover Of DCC Controlled Device | ENO Certificates |
| 24 | 6.17 | Issue Security Credential | Digital Signature - ESME |
| 24.1 | — | Retrieve Certificate From SMKI | — |
| 25 | 6.15.2 | Update Security Credential (Device) | Digital Signature - ESME |
| 26 | 6.17 | Issue Security Credential | Key Agreement Key - ESME |
| 26.1 | — | Retrieve Certificate From SMKI | — |
| 27 | 6.15.2 | Update Security Credential (Device) | Key Agreement Key - ESME |